The development of inhibitory antibodies to factor VIII is a serious complication of hemophilia. FEIBA (factor VIII inhibitor-bypassing activity), an activated prothrombin complex concentrate (aPCC), and NovoSeven, recombinant factor VIIa (rFVIIa), are used as hemostatic bypassing agents in treating patients with inhibitors. The FENOC study was designed to test equivalence of the products in the treatment of ankle, knee, and elbow joint bleeding. A prospective, open-label, randomized, crossover, equivalency design was used. The parameters of interest were the percentage of patients who reported efficacy in response to FEIBA and the percentage that reported efficacy in response to NovoSeven. A difference in these percentages of no more than 15% was determined to be a clinically acceptable magnitude for equivalence of the 2 products. The primary outcome was evaluation 6 hours after treatment. Data for 96 bleeding episodes contributed by 48 participants were analyzed. The criterion for declaring the 2 products equivalent at 6 hours was not met; however, the confidence interval of the difference in percentages of efficacy reported for each product only slightly exceeded the 15% boundary (-11.4%-15.7%), P = .059. FEIBA and NovoSeven appear to exhibit a similar effect on joint bleeds, although the efficacy between products is rated differently by a substantial proportion of patients. This trial was registered at www.clinicaltrials.gov as #NCT00166309.

A randomized comparison of bypassing agents in hemophilia complicated by an inhibitor : the FEIBA NovoSeven Comparative (FENOC) Study / J. Astermark, S.M. Donfield, D.M. Di Michele, A. Gringeri, S.A. Gilbert, J. Waters, E. Berntorp, FENOC Study Group. - In: BLOOD. - ISSN 0006-4971. - 109:2(2007 Jan 15), pp. 545-551.

A randomized comparison of bypassing agents in hemophilia complicated by an inhibitor : the FEIBA NovoSeven Comparative (FENOC) Study

A. Gringeri;
2007

Abstract

The development of inhibitory antibodies to factor VIII is a serious complication of hemophilia. FEIBA (factor VIII inhibitor-bypassing activity), an activated prothrombin complex concentrate (aPCC), and NovoSeven, recombinant factor VIIa (rFVIIa), are used as hemostatic bypassing agents in treating patients with inhibitors. The FENOC study was designed to test equivalence of the products in the treatment of ankle, knee, and elbow joint bleeding. A prospective, open-label, randomized, crossover, equivalency design was used. The parameters of interest were the percentage of patients who reported efficacy in response to FEIBA and the percentage that reported efficacy in response to NovoSeven. A difference in these percentages of no more than 15% was determined to be a clinically acceptable magnitude for equivalence of the 2 products. The primary outcome was evaluation 6 hours after treatment. Data for 96 bleeding episodes contributed by 48 participants were analyzed. The criterion for declaring the 2 products equivalent at 6 hours was not met; however, the confidence interval of the difference in percentages of efficacy reported for each product only slightly exceeded the 15% boundary (-11.4%-15.7%), P = .059. FEIBA and NovoSeven appear to exhibit a similar effect on joint bleeds, although the efficacy between products is rated differently by a substantial proportion of patients. This trial was registered at www.clinicaltrials.gov as #NCT00166309.
Comparison ; bypassing agents ; hemophilia ; inhibitor ; FEIBA NovoSeven ; FENOC
Settore MED/09 - Medicina Interna
15-gen-2007
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/157445
Citazioni
  • ???jsp.display-item.citation.pmc??? 80
  • Scopus 389
  • ???jsp.display-item.citation.isi??? 360
social impact