This paper deals with the results deriving from the elaboration of the reports on the data of the technical characteristics, the performance and the use conditions of the sprayers inspected by the accredited Centres in Lombardy, carried out from 1999 until 2020. With particular focus on the information drawn after the coming in force of the inspections mandatory (2016), the sprayers fleet highlighted first of all a difficult replacement of older machines. Furthermore, an other important point was the ascertainment of some components necessarily present on the machines subject to inspection (e.g. hand wash tank, safety valve on the filter, etc.). The old and worn condition of the fleet led also to the detection of a significant amount of malfunctions, mainly involving the filter system and the hydraulic circuit, considering the machine components, and the flow rate regulation and the distribution diagram conformity, under the performance point of view.

Check and calibration of spraying machinery in Lombardy: activity results from 1999 / D. Facchinetti, L.E. Galli, D. Pessina - In: 2021 IEEE International Workshop on Metrology for Agriculture and Forestry (MetroAgriFor)[s.l] : IEEE, 2021. - ISBN 978-1-6654-0533-1. - pp. 362-366 (( convegno International Workshop on Metrology for Agriculture and Forestry (MetroAgriFor) tenutosi a Trento-Bolzano nel 2021 [10.1109/MetroAgriFor52389.2021.9628408].

Check and calibration of spraying machinery in Lombardy: activity results from 1999

D. Facchinetti
Primo
;
L.E. Galli
Secondo
;
D. Pessina
Ultimo
2021

Abstract

This paper deals with the results deriving from the elaboration of the reports on the data of the technical characteristics, the performance and the use conditions of the sprayers inspected by the accredited Centres in Lombardy, carried out from 1999 until 2020. With particular focus on the information drawn after the coming in force of the inspections mandatory (2016), the sprayers fleet highlighted first of all a difficult replacement of older machines. Furthermore, an other important point was the ascertainment of some components necessarily present on the machines subject to inspection (e.g. hand wash tank, safety valve on the filter, etc.). The old and worn condition of the fleet led also to the detection of a significant amount of malfunctions, mainly involving the filter system and the hydraulic circuit, considering the machine components, and the flow rate regulation and the distribution diagram conformity, under the performance point of view.
health and safety; pesticide, tests; software; database
Settore AGR/09 - Meccanica Agraria
2021
MiPaaf, Università di Trento, Università di Bolzano
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
Check_and_calibration_of_spraying_machinery_in_Lombardy_activity_results_from_1999.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 2.26 MB
Formato Adobe PDF
2.26 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/888611
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact