Background The purpose of this study was to evaluate electromyography (EMG) amplitude and latency changes during tube dislocation in monitored thyroid surgery, which may be observed without recurrent laryngeal nerve injury. Methods Duroc-Landrace piglets were intubated with the TriVantage EMG tube. We measured EMG changes during both upward and downward tube dislocation (10-20 mm) and rotation (45-90°) with continuous neuromonitoring. Results The EMG amplitude varied significantly with induced endotracheal tube rotation and depth changes. However, the EMG latency was relatively unaffected by such tube dislocation, just a transient artifactual latency change was observed in the situation of extreme amplitude variation. Conclusion Amplitude changes without latency changes may be due to changes in tube position alone during surgery, but could still reflect a neurophysiologic event; amplitude changes during neuropraxic injury merit additional investigation. Thus, the combined event (concordant amplitude decrease and latency increase) serves as an appropriate adverse EMG event correlating with impending neural injury.

Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery : Results from the Porcine Experiment / Y. Kim Hoon, P. Tufano Ralph, G. Randolph, M. Barczyński, W. Wu Che, Y. Chiang Feng, X. Liu, H. Masuoka, A. Miyauchi, Y. Park Soo, Y. Kwak Hee, Y. Lee Hye, G. Dionigi. - In: HEAD & NECK. - ISSN 1043-3074. - 38:suppl. 1(2016), pp. E1004-E1008. [10.1002/hed.24145]

Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery : Results from the Porcine Experiment

G. Dionigi
Ultimo
2016

Abstract

Background The purpose of this study was to evaluate electromyography (EMG) amplitude and latency changes during tube dislocation in monitored thyroid surgery, which may be observed without recurrent laryngeal nerve injury. Methods Duroc-Landrace piglets were intubated with the TriVantage EMG tube. We measured EMG changes during both upward and downward tube dislocation (10-20 mm) and rotation (45-90°) with continuous neuromonitoring. Results The EMG amplitude varied significantly with induced endotracheal tube rotation and depth changes. However, the EMG latency was relatively unaffected by such tube dislocation, just a transient artifactual latency change was observed in the situation of extreme amplitude variation. Conclusion Amplitude changes without latency changes may be due to changes in tube position alone during surgery, but could still reflect a neurophysiologic event; amplitude changes during neuropraxic injury merit additional investigation. Thus, the combined event (concordant amplitude decrease and latency increase) serves as an appropriate adverse EMG event correlating with impending neural injury.
thyroid; recurrent laryngeal nerve; electromyography; amplitude; latency
Settore MED/18 - Chirurgia Generale
2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
Kim_et_al-2015-Head_&_Neck.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/887522
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 44
social impact