Background: In COVID-19, higher than expected level of intrapulmonary shunt has been described, in association with a discrepancy between the initial relatively preserved lung mechanics and the hypoxia severity. This study aim was to measure the shunt fraction and variations of PaO2/FiO2 ratio and oxygen alveolar-arterial gradient (A-a O2) at different FiO2. Methods: Shunt was measured by a non-invasive system during spontaneous breathing in 12 patients hospitalized at COVID-19 Semi-Intensive Care Unit of Papa Giovanni XXIII Hospital, Bergamo, Italy, between October 22 and November 23, 2020. Results: Nine patients were men, mean age (±SD) 62±15 years, mean BMI 27.5±4.8 Kg/m2. Systemic hypertension, diabetes type 2 and previous myocardial infarction were referred in 33%, 17%, and 7%, respectively. Mean PaO2/FiO2 ratio was 234±66 and 11 patients presented a bilateral chest X-ray involvement. Mean shunt was 21±6%. Mainly in patients with a more severe respiratory failure, we found a progressive decrease of PaO2/FiO2 ratio with higher FiO2. Considering (A-a O2), we found a uniform tendency to increase with FiO2 increasing. Even in this case, the more severe were the patients, the higher was the slope, suggesting FiO2 insensitiveness due to a shunt effect, as strengthened by our measurements. Conclusion: Relying on a single evaluation of PaO2/FiO2 ratio, especially at high FiO2, could be misleading in COVID-19. We propose a two steps evaluation, the first at low SpO2 value (e.g., 92-94%) and the second one at high FiO2 (i.e., >0.7), allowing to characterize both the amendable (ventilation/perfusion mismatch), and the fixed (shunt) contribution quote of respiratory impairment, respectively.

Worsening of gas exchange parameters at high FiO2 in COVID-19: Misleading or informative? / F. Raimondi, L. Novelli, G. Marchesi, F. Fabretti, L. Grazioli, I. Riva, C. Allegri, R. Biza, C. Galimberti, F.L. Lorini, F. Di Marco. - In: MULTIDISCIPLINARY RESPIRATORY MEDICINE. - ISSN 1828-695X. - 16:1(2021 May 25), pp. 1-4. [10.4081/MRM.2021.759]

Worsening of gas exchange parameters at high FiO2 in COVID-19: Misleading or informative?

F. Raimondi;C. Allegri;R. Biza;F. Di Marco
Ultimo
2021

Abstract

Background: In COVID-19, higher than expected level of intrapulmonary shunt has been described, in association with a discrepancy between the initial relatively preserved lung mechanics and the hypoxia severity. This study aim was to measure the shunt fraction and variations of PaO2/FiO2 ratio and oxygen alveolar-arterial gradient (A-a O2) at different FiO2. Methods: Shunt was measured by a non-invasive system during spontaneous breathing in 12 patients hospitalized at COVID-19 Semi-Intensive Care Unit of Papa Giovanni XXIII Hospital, Bergamo, Italy, between October 22 and November 23, 2020. Results: Nine patients were men, mean age (±SD) 62±15 years, mean BMI 27.5±4.8 Kg/m2. Systemic hypertension, diabetes type 2 and previous myocardial infarction were referred in 33%, 17%, and 7%, respectively. Mean PaO2/FiO2 ratio was 234±66 and 11 patients presented a bilateral chest X-ray involvement. Mean shunt was 21±6%. Mainly in patients with a more severe respiratory failure, we found a progressive decrease of PaO2/FiO2 ratio with higher FiO2. Considering (A-a O2), we found a uniform tendency to increase with FiO2 increasing. Even in this case, the more severe were the patients, the higher was the slope, suggesting FiO2 insensitiveness due to a shunt effect, as strengthened by our measurements. Conclusion: Relying on a single evaluation of PaO2/FiO2 ratio, especially at high FiO2, could be misleading in COVID-19. We propose a two steps evaluation, the first at low SpO2 value (e.g., 92-94%) and the second one at high FiO2 (i.e., >0.7), allowing to characterize both the amendable (ventilation/perfusion mismatch), and the fixed (shunt) contribution quote of respiratory impairment, respectively.
ARDS; COVID-19; Pneumonia; SARS-CoV-2; Shunt
Settore MED/10 - Malattie dell'Apparato Respiratorio
25-mag-2021
15-gen-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
2021 RMR Shunt Raimondi et al.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 211.2 kB
Formato Adobe PDF
211.2 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/859138
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact