Aim: To evaluate the performance of a new catheter design based on different hydrodynamics aiming to reduce the development of biofilm, and compare it with a conventional Foley catheter (FC). Methods: The new proposed design (NPD) catheter is a modification of the FC, based on asymmetric positioning of the balloon and additional drainage holes allowing continuous urine drainage and complete voiding of the bladder. A first experiment was undertaken to assess drainage capability, and a second experiment was performed using a bioreactor with a set-up simulating the bladder and using the test catheter as a flow-through system. The biofilm formation of five bacterial species associated with catheter-associated urinary tract infection (CAUTI) was determined after 24 h of incubation using an MTT assay. Morphological evaluation was performed using scanning electron microscopy. In-vitro determination of residual fluid, and quantitative and morphological data on biofilm formation on the intravesical and intraluminal parts of the tested catheters were assessed. Results: Residual fluid was significantly higher in the FC (5.60 ± 0.43 mL) compared with the NPD catheter (0.2 ± 0.03 mL). The NPD catheter showed significantly less biofilm formation (P<0.0001) than the FC. Catheter design had a variable effect on biofilm formation depending on the bacterial strain tested. There was significantly less intraluminal biomass compared with intravesical biomass in both catheters (P<0.0001). Multi-layered biofilms that covered the FC surfaces completely were seen for all tested strains, while the NPD catheter surfaces showed reduced biofilm formation. Conclusions: Modifications of the hydrodynamic characteristics of a catheter can significantly reduce bacterial colonization. Integrated design approaches combining chemical, mechanical and topographical elements can help to reduce the occurrence of CAUTI.

A new urinary catheter design reduces in-vitro biofilm formation by influencing hydrodynamics / A.C. Ionescu, E. Brambilla, M.C. Sighinolfi, R. Mattina. - In: THE JOURNAL OF HOSPITAL INFECTION. - ISSN 0195-6701. - 114(2021 Aug), pp. 153-162. [10.1016/j.jhin.2021.01.033]

A new urinary catheter design reduces in-vitro biofilm formation by influencing hydrodynamics

A.C. Ionescu
Primo
;
E. Brambilla
Secondo
;
R. Mattina
Ultimo
2021

Abstract

Aim: To evaluate the performance of a new catheter design based on different hydrodynamics aiming to reduce the development of biofilm, and compare it with a conventional Foley catheter (FC). Methods: The new proposed design (NPD) catheter is a modification of the FC, based on asymmetric positioning of the balloon and additional drainage holes allowing continuous urine drainage and complete voiding of the bladder. A first experiment was undertaken to assess drainage capability, and a second experiment was performed using a bioreactor with a set-up simulating the bladder and using the test catheter as a flow-through system. The biofilm formation of five bacterial species associated with catheter-associated urinary tract infection (CAUTI) was determined after 24 h of incubation using an MTT assay. Morphological evaluation was performed using scanning electron microscopy. In-vitro determination of residual fluid, and quantitative and morphological data on biofilm formation on the intravesical and intraluminal parts of the tested catheters were assessed. Results: Residual fluid was significantly higher in the FC (5.60 ± 0.43 mL) compared with the NPD catheter (0.2 ± 0.03 mL). The NPD catheter showed significantly less biofilm formation (P<0.0001) than the FC. Catheter design had a variable effect on biofilm formation depending on the bacterial strain tested. There was significantly less intraluminal biomass compared with intravesical biomass in both catheters (P<0.0001). Multi-layered biofilms that covered the FC surfaces completely were seen for all tested strains, while the NPD catheter surfaces showed reduced biofilm formation. Conclusions: Modifications of the hydrodynamic characteristics of a catheter can significantly reduce bacterial colonization. Integrated design approaches combining chemical, mechanical and topographical elements can help to reduce the occurrence of CAUTI.
Bacteria; Biofilm; CAUTI; Catheter; Hydrodynamic stress;
Settore MED/28 - Malattie Odontostomatologiche
ago-2021
29-apr-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
2021 Urinary catheters.pdf

accesso aperto

Tipologia: Pre-print (manoscritto inviato all'editore)
Dimensione 4.59 MB
Formato Adobe PDF
4.59 MB Adobe PDF Visualizza/Apri
1-s2.0-S0195670121001110-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 2.37 MB
Formato Adobe PDF
2.37 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/851069
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact