Background: To examine intraheartbeat displacements (IHD) and geometrical changes of endografts for abdominal aortic aneurysm repair over the course of years, defined as follow-up displacements (FUD), and to correlate them with computational fluid dynamics (CFD). Despite the widespread use of endovascular aneurysm repair (EVAR), we still know little about endograft behavior after deployment. Methods: Two cases, treated with either expanded polytetrafluoroethylene on a nitinol stent frame (PI) or with woven polyester fabric sutured to a stainless-steel Z stent skeleton (PII), were submitted to dynamic computed tomography angiography at 1, 12, and 60 months after implantation. After segmentation, IHD were computed as displacements of the reconstructed surface with respect to the diastolic instant. Similarly, FUD were studied using imaging techniques that align temporal successive segmentations. In addition, numerical simulations for blood dynamics were performed to compute viscous forces, specifically wall shear stress and time-averaged wall shear stress (TAWSS). Results: IHD analysis showed slight translations without deformation for the PI endograft with respect to the stiffer stainless-steel endograft behavior of PII. FUD showed in PI motion of the metallic struts mainly focused on the distal main body of the endograft and in the zone overlapping with iliac branches. In PII, we observed a huge FUD in the middle and inferior-anterior regions of the main body. CFD analysis revealed changes of velocity patterns associated with remodeling of the iliac zone for PI and of the main body region for PII, where flow impinges the lumen wall and progressively induces deformation of the endograft wires. Measurement of TAWSS demonstrated flow disturbances in the enlarged region correlated with displacement analysis. Conclusions: Image-based displacement analysis associated with CFD enabled very subtle evaluations of endograft behavior on different temporal scales. This kind of study could be helpful both for physicians, forecasting evolution during the life span of the endograft, and manufacturers, giving them useful information about endograft implant performance and design.

Image-Based Displacements Analysis and Computational Blood Dynamics after Endovascular Aneurysm Repair / M. Domanin, G. Piazzoli, S. Trimarchi, C. Vergara. - In: ANNALS OF VASCULAR SURGERY. - ISSN 0890-5096. - 69(2020 Nov), pp. 400-412.

Image-Based Displacements Analysis and Computational Blood Dynamics after Endovascular Aneurysm Repair

M. Domanin
;
S. Trimarchi;
2020

Abstract

Background: To examine intraheartbeat displacements (IHD) and geometrical changes of endografts for abdominal aortic aneurysm repair over the course of years, defined as follow-up displacements (FUD), and to correlate them with computational fluid dynamics (CFD). Despite the widespread use of endovascular aneurysm repair (EVAR), we still know little about endograft behavior after deployment. Methods: Two cases, treated with either expanded polytetrafluoroethylene on a nitinol stent frame (PI) or with woven polyester fabric sutured to a stainless-steel Z stent skeleton (PII), were submitted to dynamic computed tomography angiography at 1, 12, and 60 months after implantation. After segmentation, IHD were computed as displacements of the reconstructed surface with respect to the diastolic instant. Similarly, FUD were studied using imaging techniques that align temporal successive segmentations. In addition, numerical simulations for blood dynamics were performed to compute viscous forces, specifically wall shear stress and time-averaged wall shear stress (TAWSS). Results: IHD analysis showed slight translations without deformation for the PI endograft with respect to the stiffer stainless-steel endograft behavior of PII. FUD showed in PI motion of the metallic struts mainly focused on the distal main body of the endograft and in the zone overlapping with iliac branches. In PII, we observed a huge FUD in the middle and inferior-anterior regions of the main body. CFD analysis revealed changes of velocity patterns associated with remodeling of the iliac zone for PI and of the main body region for PII, where flow impinges the lumen wall and progressively induces deformation of the endograft wires. Measurement of TAWSS demonstrated flow disturbances in the enlarged region correlated with displacement analysis. Conclusions: Image-based displacement analysis associated with CFD enabled very subtle evaluations of endograft behavior on different temporal scales. This kind of study could be helpful both for physicians, forecasting evolution during the life span of the endograft, and manufacturers, giving them useful information about endograft implant performance and design.
Settore MED/22 - Chirurgia Vascolare
Settore ING-IND/06 - Fluidodinamica
nov-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
domanin2020.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 3.48 MB
Formato Adobe PDF
3.48 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/781846
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact