Background In previous studies, the Valsalva graft's compliance at the level of the Dacron pseudosinuses was found similar to that of normal sinuses shortly (2 ± 1 months) after the operation. We sought to investigate with cardiac magnetic resonance the compliance of the Valsalva graft pseudosinuses at midterm follow-up. Methods Seven patients (group A) and 7 age-matched controls (group B) were studied with steady-state free precession and phase-contrast cardiac magnetic resonance for aortic root and ascending aorta evaluation. Blood pressure was measured during phase-contrast acquisition to derive the following mechanical properties of the vascular prosthesis: pulsatility, compliance, distensibility, and elastic modulus. Results Mean postoperative follow-up was 55 ± 9.84 months. Mean age was 69.2 ± 4.98 years in group A, and 65.7 ± 7.16 years in group B. All the studied variables were coherent in showing a significant difference between the two groups, and between aortic root (skirt portion of the graft) and ascending aorta (tubular part of the graft) in group A. The presence of periaortic fibrosis did not show any correlation with the ascending aorta's mechanical properties. Conclusions At midterm follow-up, the pseudosinuses compliance of the Valsalva graft is still appreciable and significantly greater than the tubular portion.

Compliance of the valsalva graft's pseudosinuses at midterm follow-up with cardiovascular magnetic resonance / L. Monti, G. Mauri, L. Balzarini, G. Tarelli, G. Brambilla, E. Vitali, D. Ornaghi, E. Citterio, F. Settepani. - In: ANNALS OF THORACIC SURGERY. - ISSN 0003-4975. - 91:1(2011), pp. 92-96. [10.1016/j.athoracsur.2010.09.023]

Compliance of the valsalva graft's pseudosinuses at midterm follow-up with cardiovascular magnetic resonance

G. Mauri;
2011

Abstract

Background In previous studies, the Valsalva graft's compliance at the level of the Dacron pseudosinuses was found similar to that of normal sinuses shortly (2 ± 1 months) after the operation. We sought to investigate with cardiac magnetic resonance the compliance of the Valsalva graft pseudosinuses at midterm follow-up. Methods Seven patients (group A) and 7 age-matched controls (group B) were studied with steady-state free precession and phase-contrast cardiac magnetic resonance for aortic root and ascending aorta evaluation. Blood pressure was measured during phase-contrast acquisition to derive the following mechanical properties of the vascular prosthesis: pulsatility, compliance, distensibility, and elastic modulus. Results Mean postoperative follow-up was 55 ± 9.84 months. Mean age was 69.2 ± 4.98 years in group A, and 65.7 ± 7.16 years in group B. All the studied variables were coherent in showing a significant difference between the two groups, and between aortic root (skirt portion of the graft) and ascending aorta (tubular part of the graft) in group A. The presence of periaortic fibrosis did not show any correlation with the ascending aorta's mechanical properties. Conclusions At midterm follow-up, the pseudosinuses compliance of the Valsalva graft is still appreciable and significantly greater than the tubular portion.
aortic root conduit; valve; replacement; dynamics; surgery; sinuses
Settore MED/36 - Diagnostica per Immagini e Radioterapia
2011
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0003497510020990-main.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 698.2 kB
Formato Adobe PDF
698.2 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/733331
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact