Telemonitoring is one of the most expedient answers to the strong need for preventive care imposed by the rapidly aging society. We propose an innovative solution to the detection of early signs of frailty by presenting a serious game controlled by a smart sensorized soft plastic ball, designed to achieve continuous home-based monitoring of muscle weakness in older adults. Design, development, and testing of the smart ball and of the game interface devised to guide the monitoring procedure are presented. Reliability and concurrent validity of the system in measuring maximal grip strength against the clinical standard Jamar® were evaluated. Serious game usability and acceptance were investigated on 26 elderlies. Smart ball and Jamar measurements were well correlated (0.76 and 0.80 for dominant and non-dominant hands) and test–retest reliability of pressure measurements was excellent (intraclass correlation coefficient >0.94). The serious game was well accepted by the 96.1 percent of participants, who provided a strongly positive usability score (87.7/100). The smart ball–driven serious game demonstrated excellent reliability and good validity in measuring grip strength. The proposed smart ball–driven serious game can be used for home self-monitoring of grip strength in elderlies.

Validity and usability of a smart ball–driven serious game to monitor grip strength in independent elderlies / F. Lunardini, N.A. Borghese, L. Piccini, G. Bernardelli, M. Cesari, S. Ferrante. - In: HEALTH INFORMATICS JOURNAL. - ISSN 1460-4582. - (2020 Jan 06). [Epub ahead of print] [10.1177/1460458219895381]

Validity and usability of a smart ball–driven serious game to monitor grip strength in independent elderlies

N.A. Borghese;G. Bernardelli;M. Cesari;
2020

Abstract

Telemonitoring is one of the most expedient answers to the strong need for preventive care imposed by the rapidly aging society. We propose an innovative solution to the detection of early signs of frailty by presenting a serious game controlled by a smart sensorized soft plastic ball, designed to achieve continuous home-based monitoring of muscle weakness in older adults. Design, development, and testing of the smart ball and of the game interface devised to guide the monitoring procedure are presented. Reliability and concurrent validity of the system in measuring maximal grip strength against the clinical standard Jamar® were evaluated. Serious game usability and acceptance were investigated on 26 elderlies. Smart ball and Jamar measurements were well correlated (0.76 and 0.80 for dominant and non-dominant hands) and test–retest reliability of pressure measurements was excellent (intraclass correlation coefficient >0.94). The serious game was well accepted by the 96.1 percent of participants, who provided a strongly positive usability score (87.7/100). The smart ball–driven serious game demonstrated excellent reliability and good validity in measuring grip strength. The proposed smart ball–driven serious game can be used for home self-monitoring of grip strength in elderlies.
aging; frailty; muscle weakness; serious game; telemonitoring
Settore MED/09 - Medicina Interna
   Multiple-actOrs Virtual Empathic CARgiver for the Elder (MoveCare)
   MoveCare
   EUROPEAN COMMISSION
   H2020
   732158
6-gen-2020
6-gen-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
1460458219895381.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 880.28 kB
Formato Adobe PDF
880.28 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/717207
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact