Dental implants rehabilitation of edentulous patients is the current accepted treatment to increase prosthetic stabilization. Various implant surface modifications have been tried to enhance osseointegration and to reduce the spread of detrimental metallic ions toward host tissues [1]. The aim of this preliminary study was to investigate in vitro the viability, proliferation and adhesion of a Bioloy® (B®) coating compared to machined and sandblasted surfaces and to assess histologically in vivo the bone response to customized mini-implants coated with B® () placed in the mandible of patients. B® is a titanium niobium nitride coating applied on surface by physical vapor deposition (Permedica Spa). It is a thin ceramic monolayer, extremely hard and with high resistance against wear, scratches and corrosion [2] Viability and adhesion was tested at 24, 48 and 72 hours after seeding of SAOS-2 on customised scaffold. Cell viability (2x104 cells) was evaluated by AlamarBlue® assay [3] and it resulted statistically higher on B® than in the other 2 groups (48 and 72 hours, p-value<0.05). No toxic response was observed. Adhesion (104 cells) was analysed by scanning electron microscope [3]. Cell morphology confirmed the healthy status. Cells adhered to the surface and proliferated, covering completely the surfaces of machined and B® at 72 hours. Osseointegration was evaluated in 2 patients. After tooth extraction, 3 MIB® were placed. Three months later, during drilling process, the biopsies with MIB® were harvested for histological processing (Donath’ protocol) [3]. In all sections MIB® resulted well osseointegrated and newly formed bone was highly mineralized and organized in lamellae (bone to implant contact 46.8%±9.15). The implant coils were filled with new bone for the 59.8% ± 4.23. Medullary spaces were rich in blood vessels without inflammatory infiltrate. In conclusion, B® is a promising coating able to enhance the viability in vitro and to favor the osseointegration in vivo. References [1] Xuereb et al. Int J Prosthodont. 2015;28(1):51-59. [2] Olivares-Navarrete et al. Coatings 2011;1(1):72-87. [3] Canciani et al. J Craniofac Surg. 2016;27(3):727-32.

Histomorphometrical evaluation of cells and tissues in contact with a new anti-wear dental implant surface: Bioloy® coating / E. Canciani, E. Galliera, M. Marazzi, G. Mondella, K. Daniel, G. Daniele, O. Andrea, C.P.B. Dellavia. - In: ITALIAN JOURNAL OF ANATOMY AND EMBRYOLOGY. - ISSN 1122-6714. - 122:suppl.(2017 Oct), pp. 45-45. (Intervento presentato al 71. convegno Meeting of the Italian Society of Anatomy and Histology tenutosi a Taormina nel 2017) [10.13128/IJAE-21437].

Histomorphometrical evaluation of cells and tissues in contact with a new anti-wear dental implant surface: Bioloy® coating

E. Canciani
Primo
;
E. Galliera;M. Marazzi;G. Mondella;C.P.B. Dellavia
2017

Abstract

Dental implants rehabilitation of edentulous patients is the current accepted treatment to increase prosthetic stabilization. Various implant surface modifications have been tried to enhance osseointegration and to reduce the spread of detrimental metallic ions toward host tissues [1]. The aim of this preliminary study was to investigate in vitro the viability, proliferation and adhesion of a Bioloy® (B®) coating compared to machined and sandblasted surfaces and to assess histologically in vivo the bone response to customized mini-implants coated with B® () placed in the mandible of patients. B® is a titanium niobium nitride coating applied on surface by physical vapor deposition (Permedica Spa). It is a thin ceramic monolayer, extremely hard and with high resistance against wear, scratches and corrosion [2] Viability and adhesion was tested at 24, 48 and 72 hours after seeding of SAOS-2 on customised scaffold. Cell viability (2x104 cells) was evaluated by AlamarBlue® assay [3] and it resulted statistically higher on B® than in the other 2 groups (48 and 72 hours, p-value<0.05). No toxic response was observed. Adhesion (104 cells) was analysed by scanning electron microscope [3]. Cell morphology confirmed the healthy status. Cells adhered to the surface and proliferated, covering completely the surfaces of machined and B® at 72 hours. Osseointegration was evaluated in 2 patients. After tooth extraction, 3 MIB® were placed. Three months later, during drilling process, the biopsies with MIB® were harvested for histological processing (Donath’ protocol) [3]. In all sections MIB® resulted well osseointegrated and newly formed bone was highly mineralized and organized in lamellae (bone to implant contact 46.8%±9.15). The implant coils were filled with new bone for the 59.8% ± 4.23. Medullary spaces were rich in blood vessels without inflammatory infiltrate. In conclusion, B® is a promising coating able to enhance the viability in vitro and to favor the osseointegration in vivo. References [1] Xuereb et al. Int J Prosthodont. 2015;28(1):51-59. [2] Olivares-Navarrete et al. Coatings 2011;1(1):72-87. [3] Canciani et al. J Craniofac Surg. 2016;27(3):727-32.
Titanium nitride; niobium; osseointegration; implant surface; histomorphometry
Settore BIO/17 - Istologia
Settore BIO/16 - Anatomia Umana
ott-2017
Article (author)
File in questo prodotto:
File Dimensione Formato  
21437-44653-1-PB.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 155.32 kB
Formato Adobe PDF
155.32 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/660072
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact