Purpose: To report the dosimetric feasibility of the radiation technique HALFMOON (Helical ALtered Fractionation for iMplant partial OmissiON) for post-mastectomy radiation therapy (PMRT) in intermediate–high-risk breast cancer patients with implant-based immediate breast reconstruction, where the clinical target volume (CTV) does not include the whole implant (implant-sparing approach). Methods: In the HALFMOON technique, the CTV consisted of skin, subcutaneous tissues, and pectoralis major muscle, excluding the implant, chest wall muscles, and rib plane. The HALFMOON plans were compared with conventionally contoured CTV plans, in which the whole implant, chest wall muscles, and ribs plane were included in the CTV, in a ratio 1:3. All patients underwent hypofractionated treatment of 40.05 Gy/15 fractions, using helical Tomotherapy®. Results: Eighteen patients undergoing HALFMOON technique were compared to 54 subjects treated with conventionally contoured CTV plans. No difference was found in the planning target volume coverage between the two groups. Conversely, a statistically relevant dose reduction in HALFMOON patients was observed for ipsilateral lung (D15%, p < 0.0001; D20%, p < 0.0001; D35%, p = 0.003), contralateral lung (D20%, p = 0.048), contralateral breast (D15%, p = 0.031; D20%, p = 0.047), and stomach (Dmean, p = 0.011). Regarding the implant, V90% and D50% decreased by 46% and 8%, respectively, in the HALFMOON plans (p < 0.0001). Conclusion: The HALFMOON approach is technically feasible and resulted in high-dose conformity of the target with a significant reduction of radiation dose delivered to implant and other organs. A clinical study is needed to assess the impact on reconstruction cosmetic outcome and local control.

HALFMOON TomoTherapy (Helical ALtered Fractionation for iMplant partial OmissiON): implant-sparing post-mastectomy radiotherapy reshaping the clinical target volume in the reconstructed breast / M.C. Leonardi, R. Spoto, E. Miglietta, S. Trivellato, E. La Rocca, R. Luraschi, P. Grosso, F. De Lorenzi, C. Fodor, S. Dicuonzo, V. Dell'Acqua, M.A. Gerardi, A. Morra, C.M. Francia, M. Rietjens, V.E. Galimberti, P. Veronesi, R. Orecchia, F. Cattani, B.A. Jereczek-Fossa. - In: JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY. - ISSN 0171-5216. - 145:7(2019 Jul), pp. 1887-1896.

HALFMOON TomoTherapy (Helical ALtered Fractionation for iMplant partial OmissiON): implant-sparing post-mastectomy radiotherapy reshaping the clinical target volume in the reconstructed breast

R. Spoto;S. Trivellato;R. Luraschi;S. Dicuonzo;V. Dell'Acqua;M.A. Gerardi;A. Morra;C.M. Francia;M. Rietjens;P. Veronesi;R. Orecchia;B.A. Jereczek-Fossa
2019

Abstract

Purpose: To report the dosimetric feasibility of the radiation technique HALFMOON (Helical ALtered Fractionation for iMplant partial OmissiON) for post-mastectomy radiation therapy (PMRT) in intermediate–high-risk breast cancer patients with implant-based immediate breast reconstruction, where the clinical target volume (CTV) does not include the whole implant (implant-sparing approach). Methods: In the HALFMOON technique, the CTV consisted of skin, subcutaneous tissues, and pectoralis major muscle, excluding the implant, chest wall muscles, and rib plane. The HALFMOON plans were compared with conventionally contoured CTV plans, in which the whole implant, chest wall muscles, and ribs plane were included in the CTV, in a ratio 1:3. All patients underwent hypofractionated treatment of 40.05 Gy/15 fractions, using helical Tomotherapy®. Results: Eighteen patients undergoing HALFMOON technique were compared to 54 subjects treated with conventionally contoured CTV plans. No difference was found in the planning target volume coverage between the two groups. Conversely, a statistically relevant dose reduction in HALFMOON patients was observed for ipsilateral lung (D15%, p < 0.0001; D20%, p < 0.0001; D35%, p = 0.003), contralateral lung (D20%, p = 0.048), contralateral breast (D15%, p = 0.031; D20%, p = 0.047), and stomach (Dmean, p = 0.011). Regarding the implant, V90% and D50% decreased by 46% and 8%, respectively, in the HALFMOON plans (p < 0.0001). Conclusion: The HALFMOON approach is technically feasible and resulted in high-dose conformity of the target with a significant reduction of radiation dose delivered to implant and other organs. A clinical study is needed to assess the impact on reconstruction cosmetic outcome and local control.
Dosimetry; Hypofractionation; Immediate breast reconstruction; Intensity-modulated radiotherapy; Post-mastectomy radiation therapy
Settore MED/18 - Chirurgia Generale
lug-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
Leonardi2019_Article_HALFMOONTomoTherapyHelicalALte.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Visualizza/Apri   Richiedi una copia