Background Mechanical chest compression (CC) is currently suggested to deliver sustained high-quality CC in a moving ambulance. This study compared the hemodynamic support provided by a mechanical piston device or manual CC during ambulance transport in a porcine model of cardiopulmonary resuscitation. Methods and Results In a simulated urban ambulance transport, 16 pigs in cardiac arrest were randomized to 18 minutes of mechanical CC with the LUCAS (n=8) or manual CC (n=8). ECG, arterial and right atrial pressure, together with end-tidal CO2 and transthoracic impedance curve were continuously recorded. Arterial lactate was assessed during cardiopulmonary resuscitation and after resuscitation. During the initial 3 minutes of cardiopulmonary resuscitation, the ambulance was stationary, while then proceeded along a predefined itinerary. When the ambulance was stationary, CC-generated hemodynamics were equivalent in the 2 groups. However, during ambulance transport, arterial and coronary perfusion pressure, and end-tidal CO2 were significantly higher with mechanical CC compared with manual CC (coronary perfusion pressure: 43±4 versus 18±4 mmHg; end-tidal CO2: 31±2 versus 19±2 mmHg, P<0.01 at 18 minutes). During cardiopulmonary resuscitation, arterial lactate was lower with mechanical CC compared with manual CC (6.6±0.4 versus 8.2±0.5 mmol/L, P<0.01). During transport, mechanical CC showed greater constancy compared with the manual CC, as represented by a higher CC fraction and a lower transthoracic impedance curve variability ( P<0.01). All animals in the mechanical CC group and 6 (75%) in the manual one were successfully resuscitated. Conclusions This model adds evidence in favor of the use of mechanical devices to provide ongoing high-quality CC and tissue perfusion during ambulance transport.

LUCAS Versus Manual Chest Compression During Ambulance Transport: A Hemodynamic Study in a Porcine Model of Cardiac Arrest / A. Magliocca, D. Olivari, D. De Giorgio, D. Zani, M. Manfredi, A. Boccardo, A. Cucino, G. Sala, G. Babini, L. Ruggeri, D. Novelli, M. Skrifvars, B. Hardig, D. Pravettoni, L. Staszewsky, R. Latini, A. Belloli, G. Ristagno. - In: JOURNAL OF THE AMERICAN HEART ASSOCIATION. CARDIOVASCULAR AND CEREBROVASCULAR DISEASE. - ISSN 2047-9980. - 8:1(2019 Jan 08). [10.1161/JAHA.118.011189]

LUCAS Versus Manual Chest Compression During Ambulance Transport: A Hemodynamic Study in a Porcine Model of Cardiac Arrest

D. Zani;M. Manfredi;A. Boccardo;G. Sala;D. Pravettoni;A. Belloli;G. Ristagno
Ultimo
2019

Abstract

Background Mechanical chest compression (CC) is currently suggested to deliver sustained high-quality CC in a moving ambulance. This study compared the hemodynamic support provided by a mechanical piston device or manual CC during ambulance transport in a porcine model of cardiopulmonary resuscitation. Methods and Results In a simulated urban ambulance transport, 16 pigs in cardiac arrest were randomized to 18 minutes of mechanical CC with the LUCAS (n=8) or manual CC (n=8). ECG, arterial and right atrial pressure, together with end-tidal CO2 and transthoracic impedance curve were continuously recorded. Arterial lactate was assessed during cardiopulmonary resuscitation and after resuscitation. During the initial 3 minutes of cardiopulmonary resuscitation, the ambulance was stationary, while then proceeded along a predefined itinerary. When the ambulance was stationary, CC-generated hemodynamics were equivalent in the 2 groups. However, during ambulance transport, arterial and coronary perfusion pressure, and end-tidal CO2 were significantly higher with mechanical CC compared with manual CC (coronary perfusion pressure: 43±4 versus 18±4 mmHg; end-tidal CO2: 31±2 versus 19±2 mmHg, P<0.01 at 18 minutes). During cardiopulmonary resuscitation, arterial lactate was lower with mechanical CC compared with manual CC (6.6±0.4 versus 8.2±0.5 mmol/L, P<0.01). During transport, mechanical CC showed greater constancy compared with the manual CC, as represented by a higher CC fraction and a lower transthoracic impedance curve variability ( P<0.01). All animals in the mechanical CC group and 6 (75%) in the manual one were successfully resuscitated. Conclusions This model adds evidence in favor of the use of mechanical devices to provide ongoing high-quality CC and tissue perfusion during ambulance transport.
ambulance transport; cardiac arrest; cardiopulmonary resuscitation; chest compression resuscitation; manual cardiopulmonary resuscitation; mechanical cardiopulmonary resuscitation
Settore MED/41 - Anestesiologia
8-gen-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
JAHA.118.011189.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.12 MB
Formato Adobe PDF
1.12 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/618363
Citazioni
  • ???jsp.display-item.citation.pmc??? 20
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 36
social impact