Introduction: In the last 20 years glycated albumin (GA) measurement has been demonstrated to be a reliable glycation marker and recently as the most innovative one in western countries. Glycated albumin has been already adopted by some Asian countries due to its usefulness in diabetes screening. The aim of the present study was to investigate for the first time the effects of different anticoagulants on GA assay. Materials and methods: From each of 60 patients a serum tube and K3EDTA, Li-Heparin and NaF-EDTA containing tubes were collected. All tubes were from Sarstedt (Verona, Italy). Glycated albumin was measured in duplicate in each sample tube in a single analytical run with quantILab glycated albumin (Instrumentation Laboratory SpA - A Werfen Company, Milan, Italy) on Architect c8000 analyser (Abbott SRL, Rome, Italy). Comparison of GA% in evaluated tubes was made by paired Wilcoxon test. Results: Median and interquartile range GA% concentrations were 15.4% (13.2 - 19.1) in serum, 15.7% (13.6 - 19.9) in K3EDTA, 15.6% (13.3 - 19.7) in Li-heparin and 15.5% (13.1 - 19.3) in NaF-EDTA samples, respectively. Glycated albumin mean relative bias respect to serum was within desirable bias derived from biological variation studies (± 2.9%) when K3EDTA (+ 2.8%), Li-heparin (+ 0.9%) or NaF-EDTA (+ 0.1%), were used as anticoagulants. Conclusions: Our results demonstrate that the GA% assay is not affected by relevant interferences when K3EDTA, Li-heparin or NaF-EDTA are used as anticoagulants, so they can be used interchangeably without a relevant impact on the clinical use of the test.

Effects of different anticoagulants on glycated albumin quantification / G. Bonetti, N. Di Gaetano, R. Paleari, F. Ceriotti. - In: BIOCHEMIA MEDICA. - ISSN 1330-0962. - 29:1(2019 Feb). [10.11613/BM.2019.010901]

Effects of different anticoagulants on glycated albumin quantification

R. Paleari
Penultimo
;
2019

Abstract

Introduction: In the last 20 years glycated albumin (GA) measurement has been demonstrated to be a reliable glycation marker and recently as the most innovative one in western countries. Glycated albumin has been already adopted by some Asian countries due to its usefulness in diabetes screening. The aim of the present study was to investigate for the first time the effects of different anticoagulants on GA assay. Materials and methods: From each of 60 patients a serum tube and K3EDTA, Li-Heparin and NaF-EDTA containing tubes were collected. All tubes were from Sarstedt (Verona, Italy). Glycated albumin was measured in duplicate in each sample tube in a single analytical run with quantILab glycated albumin (Instrumentation Laboratory SpA - A Werfen Company, Milan, Italy) on Architect c8000 analyser (Abbott SRL, Rome, Italy). Comparison of GA% in evaluated tubes was made by paired Wilcoxon test. Results: Median and interquartile range GA% concentrations were 15.4% (13.2 - 19.1) in serum, 15.7% (13.6 - 19.9) in K3EDTA, 15.6% (13.3 - 19.7) in Li-heparin and 15.5% (13.1 - 19.3) in NaF-EDTA samples, respectively. Glycated albumin mean relative bias respect to serum was within desirable bias derived from biological variation studies (± 2.9%) when K3EDTA (+ 2.8%), Li-heparin (+ 0.9%) or NaF-EDTA (+ 0.1%), were used as anticoagulants. Conclusions: Our results demonstrate that the GA% assay is not affected by relevant interferences when K3EDTA, Li-heparin or NaF-EDTA are used as anticoagulants, so they can be used interchangeably without a relevant impact on the clinical use of the test.
anticoagulants; diabetes mellitus; preanalytical phase; serum albumin; clinical biochemistry; biochemistry (medical)
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
feb-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
A_54_2019_GA anticoag_Biochem Med.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 157.15 kB
Formato Adobe PDF
157.15 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/617000
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact