Foundation piles are being increasingly equipped with heat exchangers to efficiently harvest shallow geothermal energy. For buildings in urban areas, continuous flight auger (CFA) piles are common owing to their speed, cost-efficiency and low noise levels. To construct a thermoactive CFA pile usually requires separate central installation of the heat exchanger. However, the energy performance of this type of pile has not been investigated systematically, with most studies focused on rotary piles where the heat exchanger is attached to the reinforcing cage. In this work, insights are provided about the main influences on the energy efficiency of thermoactive CFA piles, with a focus on the implications of using CFA construction techniques rather than rotary boring. An innovative three-dimensional numerical model, able to capture the different aspects of transient heat transfer, is employed together with analytical methods to evaluate the transient and steady-state behaviour of energy piles in a number of design situations. Attention is given to understanding the role of possible pipe-to-pipe interaction, which cannot be systematically investigated with standard methods. Finally, practical guidelines on the optimal choice of design parameters to maximise the energy efficiency of CFA piles, without altering the geotechnical arrangements, are provided.

Thermal performance of thermoactive continuous flight auger piles / F. Loveridge, F. Cecinato. - In: ENVIRONMENTAL GEOTECHNICS. - ISSN 2051-803X. - 3:4(2016), pp. 265-279. [10.1680/jenge.15.00023]

Thermal performance of thermoactive continuous flight auger piles

F. Cecinato
Secondo
2016

Abstract

Foundation piles are being increasingly equipped with heat exchangers to efficiently harvest shallow geothermal energy. For buildings in urban areas, continuous flight auger (CFA) piles are common owing to their speed, cost-efficiency and low noise levels. To construct a thermoactive CFA pile usually requires separate central installation of the heat exchanger. However, the energy performance of this type of pile has not been investigated systematically, with most studies focused on rotary piles where the heat exchanger is attached to the reinforcing cage. In this work, insights are provided about the main influences on the energy efficiency of thermoactive CFA piles, with a focus on the implications of using CFA construction techniques rather than rotary boring. An innovative three-dimensional numerical model, able to capture the different aspects of transient heat transfer, is employed together with analytical methods to evaluate the transient and steady-state behaviour of energy piles in a number of design situations. Attention is given to understanding the role of possible pipe-to-pipe interaction, which cannot be systematically investigated with standard methods. Finally, practical guidelines on the optimal choice of design parameters to maximise the energy efficiency of CFA piles, without altering the geotechnical arrangements, are provided.
energy geotechnics; piles & piling; thermal effects
Settore ICAR/07 - Geotecnica
2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
ENVGEO_preprint.pdf

accesso aperto

Tipologia: Pre-print (manoscritto inviato all'editore)
Dimensione 2.67 MB
Formato Adobe PDF
2.67 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/616320
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact