Purpose: To present a simplified method for assessment of precision of fit between screw-retained frameworks and supporting implants in clinical situations. Materials and Methods: Torque-angle signature analysis is a method for analysis of tension within a joint. The OsseoCare device developed by Nobel Biocare was utilized for the tests. Three titanium frameworks were fabricated on the same master cast according to 3 different methods: (1) 1-piece casting, (2) the CNC (computer numeric controlled) method, and (3) the CTiP (Cresco Ti Precision) method. These frameworks were used to test the device and indirectly the application of the torque-angle signature analysis technology. Results: The frameworks fabricated according to the CNC and CTiP methods demonstrated OsseoCare tracings similar to the reference models of passively fitting joints, while the 1-piece cast framework did not. Conclusion: According to this pilot study, the OsseoCare device and torque-angle signature analysis proved to be feasible for clinical assessment of fit between frameworks and supporting implants.

A simplified method to assess precision of fit between framework and supporting implants. A preliminary study / A. Calderini, C. Maiorana, G. Garlini, T. Abbondanza. - In: INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS. - ISSN 0882-2786. - 22:5(2007 Sep), pp. 831-838.

A simplified method to assess precision of fit between framework and supporting implants. A preliminary study

C. Maiorana
Secondo
;
2007

Abstract

Purpose: To present a simplified method for assessment of precision of fit between screw-retained frameworks and supporting implants in clinical situations. Materials and Methods: Torque-angle signature analysis is a method for analysis of tension within a joint. The OsseoCare device developed by Nobel Biocare was utilized for the tests. Three titanium frameworks were fabricated on the same master cast according to 3 different methods: (1) 1-piece casting, (2) the CNC (computer numeric controlled) method, and (3) the CTiP (Cresco Ti Precision) method. These frameworks were used to test the device and indirectly the application of the torque-angle signature analysis technology. Results: The frameworks fabricated according to the CNC and CTiP methods demonstrated OsseoCare tracings similar to the reference models of passively fitting joints, while the 1-piece cast framework did not. Conclusion: According to this pilot study, the OsseoCare device and torque-angle signature analysis proved to be feasible for clinical assessment of fit between frameworks and supporting implants.
Settore MED/28 - Malattie Odontostomatologiche
set-2007
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/61360
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 15
social impact