Objectives: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA). Background: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. Methods: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). Results: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups. Conclusion: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES.

Risk and timing of clinical events according to diabetic status of patients treated with everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting stent : 2-year results from a propensity score matched comparison of ABSORB EXTEND and SPIRIT trials / C.M. Campos, A. Caixeta, M. Franken, A.L. Bartorelli, R.J. Whitbourn, C. Wu, H. Li Paul Kao, M.A. Rosli, D. Carrie, B. De Bruyne, G.W. Stone, P.W. Serruys, A. Abizaid. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - 91:3(2018), pp. 387-395. [10.1002/ccd.27109]

Risk and timing of clinical events according to diabetic status of patients treated with everolimus-eluting bioresorbable vascular scaffolds versus everolimus-eluting stent : 2-year results from a propensity score matched comparison of ABSORB EXTEND and SPIRIT trials

A.L. Bartorelli;
2018

Abstract

Objectives: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA). Background: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. Methods: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). Results: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups. Conclusion: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES.
bioabsorbable devices/polymers; coronary artery disease; DES-stent; diabetes mellitus; drug eluting; Radiology, Nuclear Medicine and Imaging; Cardiology and Cardiovascular Medicine
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
2018
Article (author)
File in questo prodotto:
File Dimensione Formato  
Campos_et_al-2018-Catheterization_and_Cardiovascular_Interventions.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 369.1 kB
Formato Adobe PDF
369.1 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/576931
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact