Radiation detectors built in high-voltage and highresistivity CMOS technology are an interesting option for the large area pixel trackers sought for the upgrade of the Large Hadron Collider experiments. A possible architecture is a hybrid design, where CMOS sensors are readout by front-end electronics coupled through a thin dielectric layer. A critical requirement is the radiation hardness of both the sensor and the front-end circuitry, up to a total dose ranging from 100 Mrad to 1 Grad (1 MGy to 10 MGy), depending on the distance from the interaction region. This paper explores the suitability of the BCD8 technology provided by STMicroelectronics for the construction of radiation-hard pixel detectors together with a technique to achieve reliability and repeatability of the hybridization process between the detector and the readout chip.

HV-CMOS detectors for high energy physics: Characterization of BCD8 technology and controlled hybridization technique / A. Andreazza, A. Castoldi, G. Chiodini, M. Citterio, G. Darbo, G. Gariano, A. Gaudiello, C. Guazzoni, V. Liberali, S. Passadore, F. Ragusa, A. Rovani, E. Ruscino, C. Sbarra, H. Shrimali, A. Sidoti, E. Zaffaroni - In: Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector Workshop (NSS/MIC/RTSD), 2016[s.l] : IEEE, 2017. - ISBN 9781509016426. - pp. 1-3 (( convegno IEEE Nuclear Science Symposium, Medical Imaging Conference and Room-Temperature Semiconductor Detector tenutosi a Strasbourg nel 2016 [10.1109/NSSMIC.2016.8069868].

HV-CMOS detectors for high energy physics: Characterization of BCD8 technology and controlled hybridization technique

A. Andreazza;V. Liberali
;
F. Ragusa;H. Shrimali;
2017

Abstract

Radiation detectors built in high-voltage and highresistivity CMOS technology are an interesting option for the large area pixel trackers sought for the upgrade of the Large Hadron Collider experiments. A possible architecture is a hybrid design, where CMOS sensors are readout by front-end electronics coupled through a thin dielectric layer. A critical requirement is the radiation hardness of both the sensor and the front-end circuitry, up to a total dose ranging from 100 Mrad to 1 Grad (1 MGy to 10 MGy), depending on the distance from the interaction region. This paper explores the suitability of the BCD8 technology provided by STMicroelectronics for the construction of radiation-hard pixel detectors together with a technique to achieve reliability and repeatability of the hybridization process between the detector and the readout chip.
Radiology, Nuclear Medicine and Imaging; Instrumentation; Nuclear and High Energy Physics; Electronic, Optical and Magnetic Materials
Settore FIS/01 - Fisica Sperimentale
Settore ING-INF/01 - Elettronica
2017
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
PID4601797.pdf

accesso riservato

Tipologia: Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Dimensione 4.51 MB
Formato Adobe PDF
4.51 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/569635
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact