Antimitochondrial antibodies (AMA) are the serum hallmark of primary biliary cirrhosis (PBC). However, AMA-positivity can be found in non-PBC sera when lower dilutions are used, thus raising issues about the specificity and sensitivity of the test. AMA reacts primarily with the lipoylated domains of pyruvate dehydrogenase-E2 (PDC-E2) which is highly conserved across species, including bacteria. We studied 77 serum samples, including 24 from patients with anti-PDC-E2-positive PBC and 53 controls (16 with autoimmune hepatitis (AIH), 10 with primary sclerosing cholangitis (PSC), and 27 healthy individuals) for their reactivities at serial dilutions (1:10, 1:20 and 1:40) against Escherichia coli DH5 alpha lysate overexpressing human PDC-E2 using immunoblotting (IB). A murine anti-human PDC-E2 monoclonal antibody (mAB) was used as control. We further studied positive sera using adsorption with a synthetic E. coli peptide sharing similarity with human PDC-E2. Finally, we verified whether a unique buffer for E. coli preparation could reduce non-specific serum reactivity. Results demonstrated that 100% of anti-PDC-E2-positive PBC and up to 38% of control sera at 1:10 dilution recognized E. coli PDC-E2 at IB while dilution tests indicated that the overall potency of PBC reactivity was 100-fold higher compared to controls. In fact, a subgroup (20-38%) of non-PBC sera were positive at low titers but lost the reactivity when absorbed with the synthetic E. coli peptide. Finally, our unique buffer reduced the reactivity of non-PBC sera as measured by ELISA. In conclusion, we demonstrated that weak cross-reactivity with E. coli PDC-E2 occurs in non-PBC sera at lower dilutions and that such reactivity is not due to AMA-positivity. The use of a specific buffer might avoid the risk of false positive AMA determinations when E. coli-expressed recombinant antigens are used

Serum reactivity against bacterial pyruvate dehydrogenase: increasing the specificity of anti-mitochondrial antibodies for the diagnosis of primary biliary cirrhosis / H. Miyakawa, A. Tanaka, C. Selmi, N. Hosoya, N. Mataki, K. Kikuchi, T. Kato, J. Arai, T. Goto, M.E. Gershwin. - In: CLINICAL & DEVELOPMENTAL IMMUNOLOGY. - ISSN 1740-2522. - 13:2-4(2006 Jun), pp. 289-294. [10.1080/17402520600668706]

Serum reactivity against bacterial pyruvate dehydrogenase: increasing the specificity of anti-mitochondrial antibodies for the diagnosis of primary biliary cirrhosis

C. Selmi;
2006

Abstract

Antimitochondrial antibodies (AMA) are the serum hallmark of primary biliary cirrhosis (PBC). However, AMA-positivity can be found in non-PBC sera when lower dilutions are used, thus raising issues about the specificity and sensitivity of the test. AMA reacts primarily with the lipoylated domains of pyruvate dehydrogenase-E2 (PDC-E2) which is highly conserved across species, including bacteria. We studied 77 serum samples, including 24 from patients with anti-PDC-E2-positive PBC and 53 controls (16 with autoimmune hepatitis (AIH), 10 with primary sclerosing cholangitis (PSC), and 27 healthy individuals) for their reactivities at serial dilutions (1:10, 1:20 and 1:40) against Escherichia coli DH5 alpha lysate overexpressing human PDC-E2 using immunoblotting (IB). A murine anti-human PDC-E2 monoclonal antibody (mAB) was used as control. We further studied positive sera using adsorption with a synthetic E. coli peptide sharing similarity with human PDC-E2. Finally, we verified whether a unique buffer for E. coli preparation could reduce non-specific serum reactivity. Results demonstrated that 100% of anti-PDC-E2-positive PBC and up to 38% of control sera at 1:10 dilution recognized E. coli PDC-E2 at IB while dilution tests indicated that the overall potency of PBC reactivity was 100-fold higher compared to controls. In fact, a subgroup (20-38%) of non-PBC sera were positive at low titers but lost the reactivity when absorbed with the synthetic E. coli peptide. Finally, our unique buffer reduced the reactivity of non-PBC sera as measured by ELISA. In conclusion, we demonstrated that weak cross-reactivity with E. coli PDC-E2 occurs in non-PBC sera at lower dilutions and that such reactivity is not due to AMA-positivity. The use of a specific buffer might avoid the risk of false positive AMA determinations when E. coli-expressed recombinant antigens are used
Autoantibodies; Cross-reactivity; Escherichia coli; Specificity
Settore MED/09 - Medicina Interna
giu-2006
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/52341
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 13
social impact