Ex vivo lung perfusion (EVLP) is a promising procedure for evaluation, reconditioning, and treatment of marginal lungs before transplantation. Small animal models can contribute to improve clinical development of this technique and represent a substantial platform for biomolecular investigations. However, to accomplish this purpose, EVLP models must sustain a prolonged reperfusion without pharmacological interventions. Currently available protocols only partly satisfy this need. The aim of the present research was accomplishment and optimization of a reproducible model for a protracted rat EVLP in the absence of anti-inflammatory treatment. A 180 min, uninjured and untreated perfusion was achieved through a stepwise implementation of the protocol. Flow rate, temperature, and tidal volume were gradually increased during the initial reperfusion phase to reduce hemodynamic and oxidative stress. Low flow rate combined with open atrium and protective ventilation strategy were applied to prevent lung damage. The videos enclosed show management of the most critical technical steps. The stability and reproducibility of the present procedure were confirmed by lung function evaluation and edema assessment. The meticulous description of the protocol provided in this paper can enable other laboratories to reproduce it effortlessly, supporting research in the EVLP field.

Ex vivo lung perfusion in the rat : Detailed procedure and videos / G.A. Bassani, C. Lonati, D. Brambilla, F. Rapido, F. Valenza, S. Gatti. - In: PLOS ONE. - ISSN 1932-6203. - 11:12(2016 Dec 09).

Ex vivo lung perfusion in the rat : Detailed procedure and videos

C. Lonati
Secondo
;
F. Rapido;F. Valenza
Ultimo
;
2016

Abstract

Ex vivo lung perfusion (EVLP) is a promising procedure for evaluation, reconditioning, and treatment of marginal lungs before transplantation. Small animal models can contribute to improve clinical development of this technique and represent a substantial platform for biomolecular investigations. However, to accomplish this purpose, EVLP models must sustain a prolonged reperfusion without pharmacological interventions. Currently available protocols only partly satisfy this need. The aim of the present research was accomplishment and optimization of a reproducible model for a protracted rat EVLP in the absence of anti-inflammatory treatment. A 180 min, uninjured and untreated perfusion was achieved through a stepwise implementation of the protocol. Flow rate, temperature, and tidal volume were gradually increased during the initial reperfusion phase to reduce hemodynamic and oxidative stress. Low flow rate combined with open atrium and protective ventilation strategy were applied to prevent lung damage. The videos enclosed show management of the most critical technical steps. The stability and reproducibility of the present procedure were confirmed by lung function evaluation and edema assessment. The meticulous description of the protocol provided in this paper can enable other laboratories to reproduce it effortlessly, supporting research in the EVLP field.
medicine (all); biochemistry, genetics and molecular biology (all); agricultural and biological sciences (all)
Settore MED/41 - Anestesiologia
9-dic-2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
Valenza_PlosOne_ExVivo_2016.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.87 MB
Formato Adobe PDF
1.87 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/488590
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 18
social impact