Objectives: To conduct a review of literature to summarize the existing MRI protocols for penile trauma, suggesting a tailored protocol to reduce costs and time of examination. Materials and methods: A systematic search was performed in Medline, Embase, Cochrane Library, and Cinahl databases from 1995 to 2015 to identify studies evaluating penis trauma with MRI examination. Studies were included if there was the description of MRI protocol with at least sequences and orthogonal planes used. We chose a systematic approach for data extraction and descriptive synthesis. Results: 12 articles were included in our study. Among the list of 12 articles: 2 were case reports, 3 were clinical series, and 7 were reviews. Clinical trials were not found. There is no unanimous consensus among the authors. Summarizing the data, the most used protocol is characterized by T2 sequences in three orthogonal planes plus T1 sequences in one plane (either axial or sagittal) without contrast medium injection. Conclusion: There is a lack of a standard protocol. A tailored protocol to answer the diagnostic question, reducing costs and time of examination, is characterized by T2 sequences in three orthogonal planes plus at least a T1 sequence (either axial or sagittal plane).

MRI of penile fracture: what should be a tailored protocol in emergency? / A.A. Esposito, C. Giannitto, C. Muzzupappa, S. Maccagnoni, F. Gadda, G. Albo, P.R. Biondetti. - In: EMERGENCY RADIOLOGY. - ISSN 1070-3004. - 121:9(2016 Sep), pp. 711-718.

MRI of penile fracture: what should be a tailored protocol in emergency?

C. Giannitto
Secondo
;
C. Muzzupappa;S. Maccagnoni;G. Albo;
2016

Abstract

Objectives: To conduct a review of literature to summarize the existing MRI protocols for penile trauma, suggesting a tailored protocol to reduce costs and time of examination. Materials and methods: A systematic search was performed in Medline, Embase, Cochrane Library, and Cinahl databases from 1995 to 2015 to identify studies evaluating penis trauma with MRI examination. Studies were included if there was the description of MRI protocol with at least sequences and orthogonal planes used. We chose a systematic approach for data extraction and descriptive synthesis. Results: 12 articles were included in our study. Among the list of 12 articles: 2 were case reports, 3 were clinical series, and 7 were reviews. Clinical trials were not found. There is no unanimous consensus among the authors. Summarizing the data, the most used protocol is characterized by T2 sequences in three orthogonal planes plus T1 sequences in one plane (either axial or sagittal) without contrast medium injection. Conclusion: There is a lack of a standard protocol. A tailored protocol to answer the diagnostic question, reducing costs and time of examination, is characterized by T2 sequences in three orthogonal planes plus at least a T1 sequence (either axial or sagittal plane).
emergency; fracture; MRI; penis; tailored protocol; urology; medicine (all); radiology, nuclear medicine and imaging
Settore MED/24 - Urologia
set-2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
art_10.1007_s11547-016-0651-4.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 540.52 kB
Formato Adobe PDF
540.52 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/462638
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 10
social impact