The response of a cylindrical continuous 3" × 3" LaBr 3 :Ce crystal coupled to four Position Sensitive photomultipliers (PSPMT) was studied using a 1 mm collimated beam of 662 keV gamma rays. The LaBr 3 :Ce crystal is sealed in a capsule and has diffusive/reflective surfaces, the energy resolution is 21 keV (FWHM) at 662 keV, measured using a R6233-100sel PMT. The PSPMTs are HAMAMATSU H8500 and have 64 segments each. Two PSPMTS have 10 dynodes and a 52 mm flat square standard Bialkali photocathode while the other two have 8 dinodes and a SBA photocathode. We performed a scan of the crystal moving the collimated source. The 256 segments of the four PSPMTs were grouped into 4 or 16 elements. The Centroid position, FWHM and area of the full energy peak were extracted from the measured spectra. The data show a regular behavior which depends on the position of the incident gamma beam. The position of the source was also calculated event by event and the positional resolution was measured.

3"x 3" LaBr3:Ce position sensitivity with multi-anode PMT readout / A. Giaz, N. Blasi, F. Camera, C. Boiano, S. Brambilla, B. Million, S. Riboldi - In: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)[s.l] : IEEE, 2016. - ISBN 9781479960972. - pp. 1-5 (( convegno IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC tenutosi a Seattle nel 2014 [10.1109/NSSMIC.2014.7431199].

3"x 3" LaBr3:Ce position sensitivity with multi-anode PMT readout

A. Giaz
Primo
;
F. Camera;S. Riboldi
Ultimo
2016

Abstract

The response of a cylindrical continuous 3" × 3" LaBr 3 :Ce crystal coupled to four Position Sensitive photomultipliers (PSPMT) was studied using a 1 mm collimated beam of 662 keV gamma rays. The LaBr 3 :Ce crystal is sealed in a capsule and has diffusive/reflective surfaces, the energy resolution is 21 keV (FWHM) at 662 keV, measured using a R6233-100sel PMT. The PSPMTs are HAMAMATSU H8500 and have 64 segments each. Two PSPMTS have 10 dynodes and a 52 mm flat square standard Bialkali photocathode while the other two have 8 dinodes and a SBA photocathode. We performed a scan of the crystal moving the collimated source. The 256 segments of the four PSPMTs were grouped into 4 or 16 elements. The Centroid position, FWHM and area of the full energy peak were extracted from the measured spectra. The data show a regular behavior which depends on the position of the incident gamma beam. The position of the source was also calculated event by event and the positional resolution was measured.
Scintillator; LaBr; Position sensitivity; Photomultiplier tube
Settore FIS/01 - Fisica Sperimentale
Settore ING-INF/01 - Elettronica
2016
Book Part (author)
File in questo prodotto:
File Dimensione Formato  
07431199.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 961.26 kB
Formato Adobe PDF
961.26 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/461930
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact