BACKGROUND Although associated with left heart pathologies, functional tricuspid regurgitation (FTR) is often left untreated during left heart surgery. Hence, owing to its degenerative character, reoperation is often needed, encompassing an impressive (25% to 35%) mortality rate. Thus transcatheter approaches to FTR are raising great interest. OBJECTIVES The authors evaluated the post-treatment effectiveness of the edge-to-edge technique using the percutaneous mitral valve repair device in an ex vivo pulsatile model of FTR. METHODS The devices were implanted in 11 porcine hearts simulating FTR. In each heart, single-clip treatments involved grasping leaflet pairs in the medial or commissural position (6 combinations). Two-clip treatments were then performed considering all possible 15 combinations of leaflet pairs and medial/commissural grasping. Cardiac output, mean pulmonary pressure, and mean diastolic valve pressure gradient were evaluated in physiological and simulated pathological conditions (FTR), and post-treatments. RESULTS Grasping the septal and anterior leaflets allowed for the best post-procedural outcome, ensuring a complete re-establishment of physiological-like hemodynamics. Septal and posterior grasping induced a significant recovery from FTR, although less marked. Conversely, grasping the anterior and posterior leaflets did not reduce FTR, and was detrimental in some specific cases. CONCLUSIONS This experimental work demonstrated that the transcatheter edge-to-edge repair technique is a feasible approach for FTR. The study investigated this approach to develop a selective, specific structural intervention methodology for treating FTR, considering the several biomechanical factors that alter proper functionality of valvular substructures. These results can be used to guide the development of edge-to-edge repair techniques in treatment of FTR.

Transcatheter Edge-to-Edge Treatment of Functional Tricuspid Regurgitation in an Ex Vivo Pulsatile Heart Model / R. Vismara, G. Gelpi, S. Prabhu, P. Romitelli, L.G. Troxler, A. Mangini, C. Romagnoni, M. Contino, D.T. Van Hoven, F. Lucherini, M. Jaworek, A. Redaelli, G.B. Fiore, C. Antona. - In: JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY. - ISSN 0735-1097. - 68:10(2016 Sep 06), pp. 1024-1033. [10.1016/j.jacc.2016.06.022]

Transcatheter Edge-to-Edge Treatment of Functional Tricuspid Regurgitation in an Ex Vivo Pulsatile Heart Model

C. Romagnoni;M. Contino;C. Antona
Ultimo
2016

Abstract

BACKGROUND Although associated with left heart pathologies, functional tricuspid regurgitation (FTR) is often left untreated during left heart surgery. Hence, owing to its degenerative character, reoperation is often needed, encompassing an impressive (25% to 35%) mortality rate. Thus transcatheter approaches to FTR are raising great interest. OBJECTIVES The authors evaluated the post-treatment effectiveness of the edge-to-edge technique using the percutaneous mitral valve repair device in an ex vivo pulsatile model of FTR. METHODS The devices were implanted in 11 porcine hearts simulating FTR. In each heart, single-clip treatments involved grasping leaflet pairs in the medial or commissural position (6 combinations). Two-clip treatments were then performed considering all possible 15 combinations of leaflet pairs and medial/commissural grasping. Cardiac output, mean pulmonary pressure, and mean diastolic valve pressure gradient were evaluated in physiological and simulated pathological conditions (FTR), and post-treatments. RESULTS Grasping the septal and anterior leaflets allowed for the best post-procedural outcome, ensuring a complete re-establishment of physiological-like hemodynamics. Septal and posterior grasping induced a significant recovery from FTR, although less marked. Conversely, grasping the anterior and posterior leaflets did not reduce FTR, and was detrimental in some specific cases. CONCLUSIONS This experimental work demonstrated that the transcatheter edge-to-edge repair technique is a feasible approach for FTR. The study investigated this approach to develop a selective, specific structural intervention methodology for treating FTR, considering the several biomechanical factors that alter proper functionality of valvular substructures. These results can be used to guide the development of edge-to-edge repair techniques in treatment of FTR.
anterior; leaflet; posterior; septal; transcatheter approach; tricuspid valve
Settore MED/23 - Chirurgia Cardiaca
6-set-2016
Article (author)
File in questo prodotto:
File Dimensione Formato  
edge to edge.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 1.36 MB
Formato Adobe PDF
1.36 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/453023
Citazioni
  • ???jsp.display-item.citation.pmc??? 15
  • Scopus 71
  • ???jsp.display-item.citation.isi??? 66
social impact