In this work, we present and discuss the use of cavity-microelectrodes (C-MEs) used as tip for the scanning electrochemical microscopy (SECM). Cavity-microelectrodes can be filled with a desired finely dispersed material thus compensating for the limited commercial availability of microwires. After discussing the possibility of filling and emptying a cavity-microelectrode with a desired tip shape, the consistency of negative and positive feedback approach curves obtained after filling a Au C-ME was verified. In addition, the tip/C-ME was tested under gas (oxygen) evolution condition, in order to demonstrate that the filling is stable in a wide range of gas fluxes thus extending the possible applications to tip generation/substrate collection mode. Finally, we introduce the use of the proposed system to quantify the rates of parallel reactions occurring at the material inserted in the tip under the tip generation/substrate collection mode.

The cavity-microelectrode as a tip for scanning electrochemical microscopy / S. Morandi, A. Minguzzi. - In: ELECTROCHEMISTRY COMMUNICATIONS. - ISSN 1388-2481. - 59(2015), pp. 100-103. [10.1016/j.elecom.2015.07.010]

The cavity-microelectrode as a tip for scanning electrochemical microscopy

S. Morandi
Primo
;
A. Minguzzi
2015

Abstract

In this work, we present and discuss the use of cavity-microelectrodes (C-MEs) used as tip for the scanning electrochemical microscopy (SECM). Cavity-microelectrodes can be filled with a desired finely dispersed material thus compensating for the limited commercial availability of microwires. After discussing the possibility of filling and emptying a cavity-microelectrode with a desired tip shape, the consistency of negative and positive feedback approach curves obtained after filling a Au C-ME was verified. In addition, the tip/C-ME was tested under gas (oxygen) evolution condition, in order to demonstrate that the filling is stable in a wide range of gas fluxes thus extending the possible applications to tip generation/substrate collection mode. Finally, we introduce the use of the proposed system to quantify the rates of parallel reactions occurring at the material inserted in the tip under the tip generation/substrate collection mode.
Approach curve; Combinatorial chemistry; Feedback mode; Generation/collection mode; Rapid screening of catalysts; SECM tip; Electrochemistry
Settore CHIM/02 - Chimica Fisica
Settore CHIM/01 - Chimica Analitica
2015
Article (author)
File in questo prodotto:
File Dimensione Formato  
35_EC_2015_C-ME_SECM.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 668.18 kB
Formato Adobe PDF
668.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/340823
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact