Background: A preparation of rabbit brain thromboplastin, provisionally coded 04/162, is proposed as a candidate for the World Health Organization (WHO) International Standard (IS) for thromboplastin (rabbit, plain), meant to replace the IS coded RBT/90 (rabbit, plain), stocks of which are now exhausted. Results: The preparation was calibrated in an international collaborative study involving 21 laboratories from13 countries and the calibration was performed against the existing WHO-IS (i.e. rTF/95 and OBT/79) and other Certified Reference Materials from the Institute for Reference Materials and Measurements of the European Commission (i.e.CRM149 S) and from the European Action on Anticoagulation (i.e. EUTHR-01). An additional candidate rabbit brain thromboplastin coded as 04/106 was also included in the study. On the basis of predefined criteria (the within- and between-laboratory precision of the calibration and the conformity to the calibration model), 04/162 was the preferred candidate. Conclusions: The assigned International Sensitivity Index value was 1.15 and the inter-laboratory SD and coefficient of variation were 0.057% and 4.9%, respectively.

International collaborative study for the calibration of a proposed international standard for thromboplastin, rabbit, plain / V. Chantarangkul, A.M. van den Besselaar, E. Witteveen, A. Tripodi. - In: JOURNAL OF THROMBOSIS AND HAEMOSTASIS. - ISSN 1538-7933. - 4:6(2006), pp. 1339-1345.

International collaborative study for the calibration of a proposed international standard for thromboplastin, rabbit, plain

A. Tripodi
Ultimo
2006

Abstract

Background: A preparation of rabbit brain thromboplastin, provisionally coded 04/162, is proposed as a candidate for the World Health Organization (WHO) International Standard (IS) for thromboplastin (rabbit, plain), meant to replace the IS coded RBT/90 (rabbit, plain), stocks of which are now exhausted. Results: The preparation was calibrated in an international collaborative study involving 21 laboratories from13 countries and the calibration was performed against the existing WHO-IS (i.e. rTF/95 and OBT/79) and other Certified Reference Materials from the Institute for Reference Materials and Measurements of the European Commission (i.e.CRM149 S) and from the European Action on Anticoagulation (i.e. EUTHR-01). An additional candidate rabbit brain thromboplastin coded as 04/106 was also included in the study. On the basis of predefined criteria (the within- and between-laboratory precision of the calibration and the conformity to the calibration model), 04/162 was the preferred candidate. Conclusions: The assigned International Sensitivity Index value was 1.15 and the inter-laboratory SD and coefficient of variation were 0.057% and 4.9%, respectively.
Settore MED/15 - Malattie del Sangue
2006
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/30151
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 23
social impact