Aims and background: The importance of optimal daily patient positioning has been stressed in order to ensure treatment reproducibitity and gain in accuracy and precision. We report our data on the 3D setup uncertainty during radiation therapy for prostate cancer using the CT image fusion technique. Methods: Ten consecutive patients scheduled for radiation therapy for prostate cancer underwent 5 prone position CT scans using an individualized immobilization cast. These different setups were analyzed using the image fusion module of the ERGO 30-Line Medical System (Milan, Italy) treatment planning system. The isocenter and the body marker displacements were measured. Results: The 3D isocenter dislocations were quantified: systematic error was Σ3D = 3.9 mm, whereas random error was σ3D = 1 mm. The mean of the minimum displacements was 0.2 ± 1 mm showing that the immobilization device used allows an accurate setup to be obtained. Single direction errors were also measured showing systematic errors, ΣAP = 2.6 mm, ΣLL = 0.6 mm, ΣSI = 3 mm in the anterior-posterior, latero-lateral, superior-inferior direction, respectively. Related random errors were σAP = 1 mm, σLL = 0.6 mm, σSI = 1.2 mm. In terms of accuracy, our uncertainties are similar to those reported in the literature. Conclusions: By applying the CT image fusion technique, a 3D study on setup accuracy was performed. We demonstrated that the use of an individualized immobilization system for prostate treatment is adequate to obtain good setup accuracy, as long as a high-quality positioning control method, such as the stereoscopic X-ray-based positioning system, is used.

CT image fusion as a tool for measuring in 3D the setup errors during conformal radiotherapy for prostate cancer / R. Cambria, F. Cattani, M. Ciocca, C. Garibaldi, G. Tosi, R. Orecchia. - In: TUMORI. - ISSN 0300-8916. - 92:2(2006 Apr), pp. 118-123.

CT image fusion as a tool for measuring in 3D the setup errors during conformal radiotherapy for prostate cancer

R. Orecchia
Ultimo
2006

Abstract

Aims and background: The importance of optimal daily patient positioning has been stressed in order to ensure treatment reproducibitity and gain in accuracy and precision. We report our data on the 3D setup uncertainty during radiation therapy for prostate cancer using the CT image fusion technique. Methods: Ten consecutive patients scheduled for radiation therapy for prostate cancer underwent 5 prone position CT scans using an individualized immobilization cast. These different setups were analyzed using the image fusion module of the ERGO 30-Line Medical System (Milan, Italy) treatment planning system. The isocenter and the body marker displacements were measured. Results: The 3D isocenter dislocations were quantified: systematic error was Σ3D = 3.9 mm, whereas random error was σ3D = 1 mm. The mean of the minimum displacements was 0.2 ± 1 mm showing that the immobilization device used allows an accurate setup to be obtained. Single direction errors were also measured showing systematic errors, ΣAP = 2.6 mm, ΣLL = 0.6 mm, ΣSI = 3 mm in the anterior-posterior, latero-lateral, superior-inferior direction, respectively. Related random errors were σAP = 1 mm, σLL = 0.6 mm, σSI = 1.2 mm. In terms of accuracy, our uncertainties are similar to those reported in the literature. Conclusions: By applying the CT image fusion technique, a 3D study on setup accuracy was performed. We demonstrated that the use of an individualized immobilization system for prostate treatment is adequate to obtain good setup accuracy, as long as a high-quality positioning control method, such as the stereoscopic X-ray-based positioning system, is used.
Dynamic micro-multileaf collimator; Image fusion; Prostate cancer; Setup uncertainty
Settore MED/36 - Diagnostica per Immagini e Radioterapia
apr-2006
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/30027
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact