During the development of a method to determine polybrominated diphenyl ethers (PBDEs) using GC/MS-MS equipped with a programmed temperature vaporizer (PTV) injector, a dramatic decrease in sensitivity to decabromodiphenyl ether (BDE-209) occurred and lack of sensitivity and repeatability was observed. An alternative method using GC/ECD equipped with an on-column injector was evaluated for this congener optimizing pre-column and column length. A coated retention gap (50 cm of length, 0.53 mm I.D., 0.15 mu m d(f)) connected to a short capillary column (7 m of length, 0.32 mm I.D., 0.25 mu m d(f)) showed the better sensitivity and repeatability. Finally, a double system based on the programmed temperature vaporizer injector/MS detector (for tri- to hepta-BDEs) and on-column injector/electron-capture detector (for BDE-209) was evaluated using two candidate certified materials (fish muscle tissue and river sediment).

Improvements in the analysis of decabromodiphenyl ether using on-column injection and electron-capture detection / A.P. Binelli, C. Roscioli, L. Guzzella. - In: JOURNAL OF CHROMATOGRAPHY A. - ISSN 0021-9673. - 1136:2(2006 Dec 15), pp. 243-247. [10.1016/j.chroma.2006.10.047]

Improvements in the analysis of decabromodiphenyl ether using on-column injection and electron-capture detection

A.P. Binelli
Primo
;
2006

Abstract

During the development of a method to determine polybrominated diphenyl ethers (PBDEs) using GC/MS-MS equipped with a programmed temperature vaporizer (PTV) injector, a dramatic decrease in sensitivity to decabromodiphenyl ether (BDE-209) occurred and lack of sensitivity and repeatability was observed. An alternative method using GC/ECD equipped with an on-column injector was evaluated for this congener optimizing pre-column and column length. A coated retention gap (50 cm of length, 0.53 mm I.D., 0.15 mu m d(f)) connected to a short capillary column (7 m of length, 0.32 mm I.D., 0.25 mu m d(f)) showed the better sensitivity and repeatability. Finally, a double system based on the programmed temperature vaporizer injector/MS detector (for tri- to hepta-BDEs) and on-column injector/electron-capture detector (for BDE-209) was evaluated using two candidate certified materials (fish muscle tissue and river sediment).
Decabromodiphenyl ether; ECD; PBDEs; Pre-columns
Settore BIO/07 - Ecologia
15-dic-2006
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/29104
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 26
social impact