Cross-talk limits of monolithic highly-segmented semiconductor detectors for high-resolution X-gamma spectrometry are investigated. Cross-talk causes false signal components yielding amplitude losses and fold-dependent shifts of the spectral lines, which partially spoil the spectroscopic performance of the detector. Two complementary electrical models are developed, which describe quantitatively the inter-channel cross-talk of monolithic segmented detectors whose electrodes are read out by charge-sensitive preamplifiers. The first is here designated as Cross-Capacitance (CC) model, the second as Split-Charge (SC) model. The CC model builds around the parasitic capacitances Cij linking the preamplifier outputs and the neighbor channel inputs. The SC model builds around the finite-value of the decoupling capacitance CC used to read out the high-voltage detector electrode. The key parameters of the models are individuated and ideas are shown to minimize their impact. Using a quasi-coaxial germanium segmented detector it is found that the SC cross-talk becomes negligible for decoupling capacitances larger than 1 nF, where instead the CC cross-talk tends to dominate. The residual cross-talk may be reduced by minimization of stray capacitances Cij, through a careful design of the layout of the Printed Circuit Board (PCB) where the input transistors are mounted. Cij can be made as low as ∼ 5 fF, but it is shown that even in such case the impact of the CC cross-talk on the detector performance is not negligible. Finally, an algorithm for cross-talk correction is presented and elaborated.

Cross-talk limits of highly segmented semiconductor detectors / A. Pullia, D. Weisshaar, F. Zocca, D. Bazzacco. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 58:3 part 3(2011 Jun), pp. 5756680.1201-5756680.1205.

Cross-talk limits of highly segmented semiconductor detectors

A. Pullia
;
F. Zocca
Penultimo
;
2011

Abstract

Cross-talk limits of monolithic highly-segmented semiconductor detectors for high-resolution X-gamma spectrometry are investigated. Cross-talk causes false signal components yielding amplitude losses and fold-dependent shifts of the spectral lines, which partially spoil the spectroscopic performance of the detector. Two complementary electrical models are developed, which describe quantitatively the inter-channel cross-talk of monolithic segmented detectors whose electrodes are read out by charge-sensitive preamplifiers. The first is here designated as Cross-Capacitance (CC) model, the second as Split-Charge (SC) model. The CC model builds around the parasitic capacitances Cij linking the preamplifier outputs and the neighbor channel inputs. The SC model builds around the finite-value of the decoupling capacitance CC used to read out the high-voltage detector electrode. The key parameters of the models are individuated and ideas are shown to minimize their impact. Using a quasi-coaxial germanium segmented detector it is found that the SC cross-talk becomes negligible for decoupling capacitances larger than 1 nF, where instead the CC cross-talk tends to dominate. The residual cross-talk may be reduced by minimization of stray capacitances Cij, through a careful design of the layout of the Printed Circuit Board (PCB) where the input transistors are mounted. Cij can be made as low as ∼ 5 fF, but it is shown that even in such case the impact of the CC cross-talk on the detector performance is not negligible. Finally, an algorithm for cross-talk correction is presented and elaborated.
Cross-talk; Germanium detectors; segmented detectors
Settore ING-INF/01 - Elettronica
Settore FIS/01 - Fisica Sperimentale
Settore FIS/04 - Fisica Nucleare e Subnucleare
giu-2011
Article (author)
File in questo prodotto:
File Dimensione Formato  
Cross-Talk Limits of Highly Segmented.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.02 MB
Formato Adobe PDF
1.02 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/289827
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact