The contribution of vasomotion to low frequency (LF, 0.03-0.14 Hz) waves in arterial pressure (AP, finger pletismography) and RR variabilities is addressed by comparing the spectra of RR, systolic AP (SAP), diastolic AP (DAP), and peripheral resistances (RES, mean AP over mean flow by laser Doppler) in the palmar region. In 22 normal volunteers, recordings were performed at rest (R) in clinostatic position and during mild exercise (EXEl, 10% maximum effort) cycling in the same position. LF predominance over the high frequency (HF, respiratory frequency) component was higher in SAP and even more in DAP than in RR; HF was virtually absent in RES. The LF central frequency shifted from 0.100 Hz for RR to 0.091 for SAP, 0.085 for DAP, and 0.073 for RES. EXEl activated LF and inhibited HF in RR; but power and frequency relationships in vascular parameters were not significantly changed

Interaction between peripheral blood flow and low frequency components in cardiovascular variability signals / A. Porta, G. Baselli, S. Cerutti, D. Lucini, L. Della Vecchia, M. Pagani. - In: COMPUTERS IN CARDIOLOGY. - ISSN 0276-6574. - 26(1999), pp. 635-638.

Interaction between peripheral blood flow and low frequency components in cardiovascular variability signals

A. Porta
Primo
;
D. Lucini;M. Pagani
Ultimo
1999

Abstract

The contribution of vasomotion to low frequency (LF, 0.03-0.14 Hz) waves in arterial pressure (AP, finger pletismography) and RR variabilities is addressed by comparing the spectra of RR, systolic AP (SAP), diastolic AP (DAP), and peripheral resistances (RES, mean AP over mean flow by laser Doppler) in the palmar region. In 22 normal volunteers, recordings were performed at rest (R) in clinostatic position and during mild exercise (EXEl, 10% maximum effort) cycling in the same position. LF predominance over the high frequency (HF, respiratory frequency) component was higher in SAP and even more in DAP than in RR; HF was virtually absent in RES. The LF central frequency shifted from 0.100 Hz for RR to 0.091 for SAP, 0.085 for DAP, and 0.073 for RES. EXEl activated LF and inhibited HF in RR; but power and frequency relationships in vascular parameters were not significantly changed
Settore MED/09 - Medicina Interna
Settore M-EDF/01 - Metodi e Didattiche delle Attivita' Motorie
Settore ING-INF/06 - Bioingegneria Elettronica e Informatica
1999
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/24923
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact