We investigated the response of a 3″ × 3″ (7.62 cm × 7.62 cm) LaBr3:Ce detector to monochromatic protons within an energy range of 70-230 MeV. The experiment was performed at the new cyclotron at the Cyclotron Centre Bronowice (CCB) of the Henryk Niewodniczański Institute of Nuclear Physics, Krakow, Poland. Protons with energies between 70 and 185 MeV were stopped inside the crystal. Three different values of PMT high voltage were used, in each case, the energy resolution, the quenching factor with respect to the gamma rays were measured. In addition, the anode pulses were acquired for both gamma rays (from a CmC source) and protons and the comparison between them will be shown.
3″ × 3″ LaBr3:Ce detector response to monochromatic protons / A. Giaz, S. Brambilla, B. Szpak, M. Zieblinski, N. Blasi, C. Boiano, F. Camera, S. Ceruti, B. Million, S. Riboldi, O. Wieland, P. Bednarczyk, M. Ciemala, B. Fornal, M. Jastrzab, M. Kmiecik, M. Krzysiek, A. Maj, W. Meczynski, P. Napiorkowski - In: IEEE Nuclear Science Symposium Conference Record[s.l] : Institute of Electrical and Electronics Engineers Inc., 2013. - ISBN 9781479905348. - pp. 1-4 (( convegno 2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 tenutosi a Seoul, kor nel 2013 [10.1109/NSSMIC.2013.6829648].
3″ × 3″ LaBr3:Ce detector response to monochromatic protons
A. Giaz;F. Camera;S. Ceruti;S. Riboldi;
2013
Abstract
We investigated the response of a 3″ × 3″ (7.62 cm × 7.62 cm) LaBr3:Ce detector to monochromatic protons within an energy range of 70-230 MeV. The experiment was performed at the new cyclotron at the Cyclotron Centre Bronowice (CCB) of the Henryk Niewodniczański Institute of Nuclear Physics, Krakow, Poland. Protons with energies between 70 and 185 MeV were stopped inside the crystal. Three different values of PMT high voltage were used, in each case, the energy resolution, the quenching factor with respect to the gamma rays were measured. In addition, the anode pulses were acquired for both gamma rays (from a CmC source) and protons and the comparison between them will be shown.File | Dimensione | Formato | |
---|---|---|---|
3__3_LaBr3Ce_detector_response_to_monochromatic_protons.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Dimensione
812.75 kB
Formato
Adobe PDF
|
812.75 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.