Background: The aim of the present study was to assess the muscular variations at the electromyography (EMG) level for the anterior temporalis muscles and masseter muscles during treatment with Occlus-o-GuideW and Andresen activator appliances. Methods: Eighty-two patients (35 males and 47 females) aged between 8 and 12 years (mean age, 10.5 ± 0.8 years) participated in the study. Fifty patients underwent treatment with an Occlus-o-GuideW and 32 patients with an Andresen activator. All patients underwent EMG examination using a Freely EMG (De Gotzen, Legnano, Italy) and surface bipolar electrodes when the appliances were worn for the first time (T0), and after 6 months (T1) and after 12 months (T2) of appliance use. Results: Statistical analysis showed that both at T0 and T2, the percent overlapping coefficient (POC) of the anterior temporalis muscles was not statistically different between the appliance groups. At T0, the POC of the masseter muscles was significantly lower for the Andresen appliance as compared to the Occlus-o-GuideW (p = 0.02), while at T2 this significance was lost. Conclusions: At insertion of an appliance, all patients show neuromuscular balance that does not correspond to orthognathic occlusion. Both appliances work by creating muscular imbalance. With the appliances in situ, EMG responses were generally analogous for the Occlus-o-GuideW and the Andresen activator; however, the imbalance was greater and the recovery of the orthological muscular balance was slower in patients under treatment with the Andresen activator as compared to those with the Occlus-o-GuideW.

Occlus-o-Guide® versus Andresen activator appliance: neuromuscular evaluation / G. Farronato, L. Giannini, G. Galbiati, E. Grillo, C. Maspero. - In: PROGRESS IN ORTHODONTICS. - ISSN 1723-7785. - 14:(2013 May 20), pp. 4.1-4.6. [10.1186/2196-1042-14-4]

Occlus-o-Guide® versus Andresen activator appliance: neuromuscular evaluation

G. Farronato
Primo
;
C. Maspero
2013

Abstract

Background: The aim of the present study was to assess the muscular variations at the electromyography (EMG) level for the anterior temporalis muscles and masseter muscles during treatment with Occlus-o-GuideW and Andresen activator appliances. Methods: Eighty-two patients (35 males and 47 females) aged between 8 and 12 years (mean age, 10.5 ± 0.8 years) participated in the study. Fifty patients underwent treatment with an Occlus-o-GuideW and 32 patients with an Andresen activator. All patients underwent EMG examination using a Freely EMG (De Gotzen, Legnano, Italy) and surface bipolar electrodes when the appliances were worn for the first time (T0), and after 6 months (T1) and after 12 months (T2) of appliance use. Results: Statistical analysis showed that both at T0 and T2, the percent overlapping coefficient (POC) of the anterior temporalis muscles was not statistically different between the appliance groups. At T0, the POC of the masseter muscles was significantly lower for the Andresen appliance as compared to the Occlus-o-GuideW (p = 0.02), while at T2 this significance was lost. Conclusions: At insertion of an appliance, all patients show neuromuscular balance that does not correspond to orthognathic occlusion. Both appliances work by creating muscular imbalance. With the appliances in situ, EMG responses were generally analogous for the Occlus-o-GuideW and the Andresen activator; however, the imbalance was greater and the recovery of the orthological muscular balance was slower in patients under treatment with the Andresen activator as compared to those with the Occlus-o-GuideW.
functional appliances; Occlus-o-Guide; activator; electromyography
Settore MED/28 - Malattie Odontostomatologiche
20-mag-2013
Article (author)
File in questo prodotto:
File Dimensione Formato  
art_10.1186_2196-1042-14-4.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 427.33 kB
Formato Adobe PDF
427.33 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/220612
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 21
  • ???jsp.display-item.citation.isi??? ND
social impact