Three flow cytometric methods of counting F cells were evaluated in the settings of an external laboratory assessment scheme. The laboratories to participate with a different method were located in Oxford (method O), Athens (method A) and Jerusalem, (method J). Two monoclonal anti-gamma chain antibodies were used: monoclonal antibody produced by P. Beverley (Oxford) (BEV) and an antibody provided by Bioatlantic S.A.R.L. (France) (BIO). The specimens tested were mixtures in five predefined ratios of a sample with homozygous deltabeta-thalassemia with 100% F cells with a sample with no F cells. A central independent laboratory prepared and distributed the aliquots (at room temperature) to the participating centers within 2 (O), 3 (A), and 6 (J) days. The performance of the three methods was evaluated by: 1) deviation indices, 2) relative accuracy, as percent difference of the counts from the target values, and 3) bias and linearity by linear regression of the counts versus the target values [parameters: slope (s), y-intercept (y), R squared (Rs), and F ratio]. The highest score of performance was obtained by method A with both monoclonal antibodies

Cross evaluation of three flow cytometric F cell counting methods performed by different laboratories / G.S. Paterakis, S.L. Thein, E. Fibach, M.D. Cappellini. - In: HEMOGLOBIN. - ISSN 0363-0269. - 23:1(1998), pp. 95-95.

Cross evaluation of three flow cytometric F cell counting methods performed by different laboratories

M.D. Cappellini
Ultimo
1998

Abstract

Three flow cytometric methods of counting F cells were evaluated in the settings of an external laboratory assessment scheme. The laboratories to participate with a different method were located in Oxford (method O), Athens (method A) and Jerusalem, (method J). Two monoclonal anti-gamma chain antibodies were used: monoclonal antibody produced by P. Beverley (Oxford) (BEV) and an antibody provided by Bioatlantic S.A.R.L. (France) (BIO). The specimens tested were mixtures in five predefined ratios of a sample with homozygous deltabeta-thalassemia with 100% F cells with a sample with no F cells. A central independent laboratory prepared and distributed the aliquots (at room temperature) to the participating centers within 2 (O), 3 (A), and 6 (J) days. The performance of the three methods was evaluated by: 1) deviation indices, 2) relative accuracy, as percent difference of the counts from the target values, and 3) bias and linearity by linear regression of the counts versus the target values [parameters: slope (s), y-intercept (y), R squared (Rs), and F ratio]. The highest score of performance was obtained by method A with both monoclonal antibodies
Erythrocytes; F cells; F erythrocytes; Fetal cells; Flow cytometry; Hb F; Methods; RBC; Red cells; Techniques
Settore MED/09 - Medicina Interna
1998
http://informahealthcare.com/loi/hem
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/219348
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 6
social impact