Purpose of review : To survey the causes of ventilator-induced lung injury focusing on its mechanical determinants, lung stress and strain. Recent findings : Tidal volume per ideal body weight (tidal volume/IBW) and airway pressure (PAW) are poor surrogates of strain and stress, which are respectively defined as the ratio of volume variation to lung resting volume and transpulmonary pressure. In healthy lungs, ventilation becomes lethal with strain reaching total lung capacity (tidal volume/IBW around 30-40 ml/kg) and with its related stress (roughly 24cmH2O). The striking discrepancy between experimental data and clinical scenarios (harm at tidal volume/IBW of 12 ml/kg) may be explained by lung dishomogeneity, locally generating 'stress risers' or 'pressure multipliers'. When mechanical ventilation becomes unsafe, as inferred from computed tomography-scan evaluation of dishomogeneity and stress/strain values, lung protective strategies can be maximized by further reducing tidal volume and increasing PAW (e.g. high frequency oscillatory ventilation). In alternative, artificial lungs may provide adequate gas exchange while reducing the load of mechanical ventilation. Recently, outcome benefit was shown with the use of this technique in H1N1 patients. Summary : When lung protective strategy is considered unsafe, various techniques of extracorporeal respiratory support may be applied, which by decreasing the load of mechanical ventilation, allow partial to total lung rest.

Towards ultraprotective mechanical ventilation / L. Gattinoni, E. Carlesso, T. Langer. - In: CURRENT OPINION IN ANAESTHESIOLOGY. - ISSN 0952-7907. - 25:2(2012 Apr), pp. 141-147. [10.1097/ACO.0b013e3283503125]

Towards ultraprotective mechanical ventilation

L. Gattinoni
Primo
;
E. Carlesso
Secondo
;
T. Langer
Ultimo
2012

Abstract

Purpose of review : To survey the causes of ventilator-induced lung injury focusing on its mechanical determinants, lung stress and strain. Recent findings : Tidal volume per ideal body weight (tidal volume/IBW) and airway pressure (PAW) are poor surrogates of strain and stress, which are respectively defined as the ratio of volume variation to lung resting volume and transpulmonary pressure. In healthy lungs, ventilation becomes lethal with strain reaching total lung capacity (tidal volume/IBW around 30-40 ml/kg) and with its related stress (roughly 24cmH2O). The striking discrepancy between experimental data and clinical scenarios (harm at tidal volume/IBW of 12 ml/kg) may be explained by lung dishomogeneity, locally generating 'stress risers' or 'pressure multipliers'. When mechanical ventilation becomes unsafe, as inferred from computed tomography-scan evaluation of dishomogeneity and stress/strain values, lung protective strategies can be maximized by further reducing tidal volume and increasing PAW (e.g. high frequency oscillatory ventilation). In alternative, artificial lungs may provide adequate gas exchange while reducing the load of mechanical ventilation. Recently, outcome benefit was shown with the use of this technique in H1N1 patients. Summary : When lung protective strategy is considered unsafe, various techniques of extracorporeal respiratory support may be applied, which by decreasing the load of mechanical ventilation, allow partial to total lung rest.
artificial lung; lung protective strategy; mechanical ventilation; strain; stress
Settore MED/41 - Anestesiologia
apr-2012
Article (author)
File in questo prodotto:
File Dimensione Formato  
218_curr_op_anest_2012.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 225.57 kB
Formato Adobe PDF
225.57 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/218408
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 35
social impact