BACKGROUND - Biological pacemakers (BPM) implanted in canine left bundle branch function competitively with electronic pacemakers (EPM). We hypothesized that BPM engineered with the use of mE324A mutant murine HCN2 (mHCN2) genes would improve function over mHCN2 and that BPM/EPM tandems confer advantage over either approach alone. METHODS AND RESULTS - In cultured neonatal rat myocytes, activation midpoint was -46.9 mV in mE324A versus -66.1 mV in mHCN2 (P<0.05). mE324A manifested a positive shift of voltage dependence of gating kinetics of activation and deactivation compared with mHCN2 (P<0.05) in myocytes as well as Xenopus oocytes. In intact dogs in complete atrioventricular block, saline (control), mHCN2, or mE324A virus was injected into left bundle branch, and EPM were implanted (VVI 45 bpm). Twenty-four-hour ECGs were monitored for 14 days. With EPM discontinued, there was no difference in duration of overdrive suppression among groups. However, basal heart rates in controls were less than those in mHCN2, which did not differ from those in E324A (45 versus 57 versus 53 bpm; P<0.05). When spontaneous rate fell below 45 bpm, EPM intervened at that rate, triggering 83% of beats in control, contrasting (P<0.05) with 26% (mHCN2) and 36% (mE324A). On day 14, epinephrine (1 μg/kg per minute IV) induced a 50% heart rate increase in all mE324A, one third of mHCN2, and one fifth of control (P<0.05 mE324A versus control or mHCN2). CONCLUSIONS - mE324A induces faster, more positive pacemaker current activation than mHCN2 and stable, catecholamine-sensitive rhythms in situ that compete with EPM comparably but more catecholamine responsively than mHCN2. BPM/EPM tandems function reliably, reduce the number of EPM beats, and confer sympathetic responsiveness to the tandem.

Wild-type and mutant HCN channels in a tandem biological-electronic cardiac pacemaker / A. Bucchi, A. Plotnikov, I. Shlapakova, P. Danilo, Y. Kryukova, J. Qu, Z. Lu, H. Liu, Z. Pan, I. Potapova, B. KenKnight, S. Girouard, I. Cohen, P. Brink, R. Robinson, M. Rosen. - In: CIRCULATION. - ISSN 0009-7322. - 114:10(2006), pp. 992-999.

Wild-type and mutant HCN channels in a tandem biological-electronic cardiac pacemaker

A. Bucchi
Primo
;
2006

Abstract

BACKGROUND - Biological pacemakers (BPM) implanted in canine left bundle branch function competitively with electronic pacemakers (EPM). We hypothesized that BPM engineered with the use of mE324A mutant murine HCN2 (mHCN2) genes would improve function over mHCN2 and that BPM/EPM tandems confer advantage over either approach alone. METHODS AND RESULTS - In cultured neonatal rat myocytes, activation midpoint was -46.9 mV in mE324A versus -66.1 mV in mHCN2 (P<0.05). mE324A manifested a positive shift of voltage dependence of gating kinetics of activation and deactivation compared with mHCN2 (P<0.05) in myocytes as well as Xenopus oocytes. In intact dogs in complete atrioventricular block, saline (control), mHCN2, or mE324A virus was injected into left bundle branch, and EPM were implanted (VVI 45 bpm). Twenty-four-hour ECGs were monitored for 14 days. With EPM discontinued, there was no difference in duration of overdrive suppression among groups. However, basal heart rates in controls were less than those in mHCN2, which did not differ from those in E324A (45 versus 57 versus 53 bpm; P<0.05). When spontaneous rate fell below 45 bpm, EPM intervened at that rate, triggering 83% of beats in control, contrasting (P<0.05) with 26% (mHCN2) and 36% (mE324A). On day 14, epinephrine (1 μg/kg per minute IV) induced a 50% heart rate increase in all mE324A, one third of mHCN2, and one fifth of control (P<0.05 mE324A versus control or mHCN2). CONCLUSIONS - mE324A induces faster, more positive pacemaker current activation than mHCN2 and stable, catecholamine-sensitive rhythms in situ that compete with EPM comparably but more catecholamine responsively than mHCN2. BPM/EPM tandems function reliably, reduce the number of EPM beats, and confer sympathetic responsiveness to the tandem.
Settore BIO/09 - Fisiologia
2006
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/211431
Citazioni
  • ???jsp.display-item.citation.pmc??? 43
  • Scopus 105
  • ???jsp.display-item.citation.isi??? 86
social impact