Many different aims must be satisfied in the design of front-end readout electronics for spectroscopy detectors (equivalent input noise, gain bandwidth and stability, etc.), some of which may result in conflicting design specifications. We propose an interactive procedure that allows the optimization of all design parameters (individual dimensions of integrated devices, resistors and capacitors values, etc.) by finding the best compromise between the possibly conflicting design goals. This is achieved in an automated way just by changing the relative weights associated with the different design goals. Implementation issues are briefly discussed and an applicative example is given. The example is based on a real circuit for cryogenic gamma rays spectroscopy. Two modified designs are obtained by the optimizing method: the first one shows improved bandwidth specifications while the second one has better noise.

A method for the optimization of front-end electronics for ionizing radiation spectrometers / D. Maiocchi, S. Riboldi, A. Pullia - In: 2005 IEEE Nuclear science symposium conference record : nuclear science symposium and medical imaging conference: October 23-29, 2005, Puerto Rico. Volume 2 / [a cura di] B. Yu. - Disco ottico. - Piscataway (New Jersey) : IEEE, 2005. - ISBN 9780780392212. - pp. 965-968 (( convegno Nuclear science symposium and medical imaging conference tenutosi a Puerto Rico (USA) nel 2005.

A method for the optimization of front-end electronics for ionizing radiation spectrometers

S. Riboldi
Secondo
;
A. Pullia
Ultimo
2005

Abstract

Many different aims must be satisfied in the design of front-end readout electronics for spectroscopy detectors (equivalent input noise, gain bandwidth and stability, etc.), some of which may result in conflicting design specifications. We propose an interactive procedure that allows the optimization of all design parameters (individual dimensions of integrated devices, resistors and capacitors values, etc.) by finding the best compromise between the possibly conflicting design goals. This is achieved in an automated way just by changing the relative weights associated with the different design goals. Implementation issues are briefly discussed and an applicative example is given. The example is based on a real circuit for cryogenic gamma rays spectroscopy. Two modified designs are obtained by the optimizing method: the first one shows improved bandwidth specifications while the second one has better noise.
design parameters ; readout electronics ; radiation spectrometers ; optimization ; radiation detectors
Settore ING-INF/01 - Elettronica
Settore FIS/01 - Fisica Sperimentale
2005
IEEE
Book Part (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/206321
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact