Aim of our work was to validate magnetic resonance angiography (MRA) in detecting occlusion/patency of coronary artery bypass grafts. Twenty patients with previous history of bypass surgery and recurrent episodes of chest pain were enrolled. Two patients could not be studied (claustrophobia, erratic breathing). Thus, 18 patients with 51 bypasses were examined using a navigator echo sequence: 21 arterial grafts (six sequential) and 30 saphenous vein grafts (five sequential). All patients had undergone contrast conventional angiography 3-15 days before MRA. The magnetic resonance (MR) data set was analyzed by two independent readers blinded to the results of conventional angiography (occlusion of 12 of 51 grafts). At magnetic resonance, two bypasses of the posterior descending artery, patent at conventional angiography, could not be visualized because of imaging slab malpositioning. Interobserver concordance was 96% (47/49). Magnetic resonance and conventional angiography provided identical answers in 47 out of 49 (96%) of the examined grafts. Eleven out of 12 occluded grafts and 36 out of 37 patent grafts were correctly identified with MR. As far as occlusion is concerned, the sensitivity of MR was 91%, the specificity 97%. To summarize, a 30 min outpatient MR examination is highly reliable in determining occlusion/patency of arterial and venous, single and sequential bypasses.

Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass grafts / G. Molinari, F. Sardanelli, F. Zandrino, M. Balbi, M. A. Masperone. - In: INTERNATIONAL JOURNAL OF CARDIAC IMAGING. - ISSN 0167-9899. - 16:3(2000 Jun), pp. 149-60-160. [10.1023/A:1006432027712]

Value of navigator echo magnetic resonance angiography in detecting occlusion/patency of arterial and venous, single and sequential coronary bypass grafts

F. Sardanelli;
2000

Abstract

Aim of our work was to validate magnetic resonance angiography (MRA) in detecting occlusion/patency of coronary artery bypass grafts. Twenty patients with previous history of bypass surgery and recurrent episodes of chest pain were enrolled. Two patients could not be studied (claustrophobia, erratic breathing). Thus, 18 patients with 51 bypasses were examined using a navigator echo sequence: 21 arterial grafts (six sequential) and 30 saphenous vein grafts (five sequential). All patients had undergone contrast conventional angiography 3-15 days before MRA. The magnetic resonance (MR) data set was analyzed by two independent readers blinded to the results of conventional angiography (occlusion of 12 of 51 grafts). At magnetic resonance, two bypasses of the posterior descending artery, patent at conventional angiography, could not be visualized because of imaging slab malpositioning. Interobserver concordance was 96% (47/49). Magnetic resonance and conventional angiography provided identical answers in 47 out of 49 (96%) of the examined grafts. Eleven out of 12 occluded grafts and 36 out of 37 patent grafts were correctly identified with MR. As far as occlusion is concerned, the sensitivity of MR was 91%, the specificity 97%. To summarize, a 30 min outpatient MR examination is highly reliable in determining occlusion/patency of arterial and venous, single and sequential bypasses.
Angiography; Bypass; Coronary disease; Heart; Magnetic resonance (MR)
Settore MED/36 - Diagnostica per Immagini e Radioterapia
giu-2000
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/201597
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 21
social impact