To test a new tool for the neurophysiological identification of the human subthalamic nucleus (STN) during stereotactic surgery for the implantation of deep-brain-stimulation (DBS) electrodes, we analysed off-line the intraoperative signals recorded from patients with Parkinson's disease. We estimated the power spectral density (PSD) along each penetration track (8 patients, 13 sides) and determined the spatial correlation of the PSD with the target location estimated from neuroimaging procedures ("anatomical target"), and with the final target location derived from standard intraoperative neurophysiological procedures for STN localization ("clinical target"). At each step we recorded the 'on-line' signal for 120 seconds; because the PSD was estimated by calculating the periodogram for 6-second epochs of neural signal, we had 20 epochs at each step. When the electrode track crossed the STN, the PSD in the 0.25-2.5 kHz band increased, peaking on average <0.5 mm cranial to the clinical target and 1.00+/-1.51 mm caudal to the anatomical target. When the track was outside the nucleus, the PSD remained unchanged. Even on recordings with low signal-tonoise ratio, off-line PSD analysis of neural signals showed a good correspondence with the target indicated by the surgical team. On-line intraoperative estimation of the PSD may be a simple, reliable, rapid and complementary approach to electrophysiological monitoring during STN surgery for Parkinson's disease.

The subthalamic nucleus in Parkinson's disease: power spectral density analysis of neural intraoperative signals / A. Pesenti, M. Rohr, M. Egidi, P. Rampini, F. Tamma, M. Locatelli, E. Caputo, V. Chiesa, A. Bianchi, S. Barbieri, G. Baselli, A. Priori. - In: NEUROLOGICAL SCIENCES. - ISSN 1590-1874. - 24:6(2004), pp. 367-374. [10.1007/s10072-003-0191-2]

The subthalamic nucleus in Parkinson's disease: power spectral density analysis of neural intraoperative signals

M. Locatelli;A. Priori
2004

Abstract

To test a new tool for the neurophysiological identification of the human subthalamic nucleus (STN) during stereotactic surgery for the implantation of deep-brain-stimulation (DBS) electrodes, we analysed off-line the intraoperative signals recorded from patients with Parkinson's disease. We estimated the power spectral density (PSD) along each penetration track (8 patients, 13 sides) and determined the spatial correlation of the PSD with the target location estimated from neuroimaging procedures ("anatomical target"), and with the final target location derived from standard intraoperative neurophysiological procedures for STN localization ("clinical target"). At each step we recorded the 'on-line' signal for 120 seconds; because the PSD was estimated by calculating the periodogram for 6-second epochs of neural signal, we had 20 epochs at each step. When the electrode track crossed the STN, the PSD in the 0.25-2.5 kHz band increased, peaking on average <0.5 mm cranial to the clinical target and 1.00+/-1.51 mm caudal to the anatomical target. When the track was outside the nucleus, the PSD remained unchanged. Even on recordings with low signal-tonoise ratio, off-line PSD analysis of neural signals showed a good correspondence with the target indicated by the surgical team. On-line intraoperative estimation of the PSD may be a simple, reliable, rapid and complementary approach to electrophysiological monitoring during STN surgery for Parkinson's disease.
Deep brain stimulation; Intraoperative monitoring; Neurophysiology; Parkinson's disease; Power spectral density analysis; Subthalamic nucleus
Settore MED/26 - Neurologia
2004
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/198882
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 22
social impact