Because of the variable responsiveness of thromboplastins to lupus anticoagulants (LA), concerns have been raised about the validity of the prothrombin time-International Normalized Ratio (PT-INR) in monitoring oral anticoagulant treatment in patients with the antiphospholipid syndrome (APS) and LA. To date, few studies have been performed, numbers of patients investigated are relatively small and results are conflicting. We report on a multicentre study organized to investigate further this clinically relevant issue. Each of nine thrombosis centres was asked to collect plasma samples from patients with APS who were on oral anticoagulants (cases) and patients without APS who were on oral anticoagulants (controls). Nine thromboplastins (three human recombinant, one from human placenta and five from rabbit brain) were calibrated at the co-ordinating centre according to World Health Organization guidelines. Measurements of the INR and factor X amidolytic activity for all frozen plasmas were performed centrally. The numbers of patients investigated were 58 cases and 57 controls. Between-reagent variability of the INR was higher in cases [coefficient of variation (CV) = 12.4%] than in controls (CV = 6.7%), but this was because of one of the thromboplastins only (Thromborel R, human recombinant), which measured considerably higher INR values than the others in cases but not in controls. In conclusion, our data indicate that LA interference on the PT-INR measured with the majority of commercial thromboplastins is not enough to cause concern if insensitive thromboplastins, properly calibrated to assign them an instrument-specific International Sensitivity Index are used. New thromboplastins, especially those made of relipidated tissue factor, should be checked for their responsiveness to LA before they are used to monitor oral anticoagulant treatment in patients with APS.

Laboratory control of oral anticoagulant treatment by the INR system in patients with the antiphospholipid syndrome and lupus anticoagulant. Results of a collaborative study involving nine commercial thromboplastins / A. Tripodi, V. Chantarangkul, M. Clerici, B. Negri, M. Galli, P.M. Mannucci. - In: BRITISH JOURNAL OF HAEMATOLOGY. - ISSN 0007-1048. - 115:3(2001), pp. 672-678.

Laboratory control of oral anticoagulant treatment by the INR system in patients with the antiphospholipid syndrome and lupus anticoagulant. Results of a collaborative study involving nine commercial thromboplastins

A. Tripodi;
2001

Abstract

Because of the variable responsiveness of thromboplastins to lupus anticoagulants (LA), concerns have been raised about the validity of the prothrombin time-International Normalized Ratio (PT-INR) in monitoring oral anticoagulant treatment in patients with the antiphospholipid syndrome (APS) and LA. To date, few studies have been performed, numbers of patients investigated are relatively small and results are conflicting. We report on a multicentre study organized to investigate further this clinically relevant issue. Each of nine thrombosis centres was asked to collect plasma samples from patients with APS who were on oral anticoagulants (cases) and patients without APS who were on oral anticoagulants (controls). Nine thromboplastins (three human recombinant, one from human placenta and five from rabbit brain) were calibrated at the co-ordinating centre according to World Health Organization guidelines. Measurements of the INR and factor X amidolytic activity for all frozen plasmas were performed centrally. The numbers of patients investigated were 58 cases and 57 controls. Between-reagent variability of the INR was higher in cases [coefficient of variation (CV) = 12.4%] than in controls (CV = 6.7%), but this was because of one of the thromboplastins only (Thromborel R, human recombinant), which measured considerably higher INR values than the others in cases but not in controls. In conclusion, our data indicate that LA interference on the PT-INR measured with the majority of commercial thromboplastins is not enough to cause concern if insensitive thromboplastins, properly calibrated to assign them an instrument-specific International Sensitivity Index are used. New thromboplastins, especially those made of relipidated tissue factor, should be checked for their responsiveness to LA before they are used to monitor oral anticoagulant treatment in patients with APS.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Settore MED/09 - Medicina Interna
Settore MED/15 - Malattie del Sangue
2001
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/189873
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 82
  • ???jsp.display-item.citation.isi??? 81
social impact