Four functional assays for protein S were evaluated by 4 different laboratories, each center using its own method. The aim of this study was to compare these different assays and to establish a relationship with results of immunological assays of total and free protein S antigen and C4bBP. The same plasma samples were distributed to each center and tested in blind. In 47 normal subjects, there was no significant difference between the 4 functional assays, with mean values ranging from 93 to 100%. These values were in good agreement with those of free and total protein S antigen. In 34 patients with a quantitative congenital deficiency of protein S the mean values of protein S activity were decreased with the 4 assays, ranging from 25 to 40%. Free protein S antigen was reduced to a similar extent, whereas total antigen was either normal or decreased. The correlation of protein S activity with free protein S antigen was satisfactory for 3 methods, with coefficients of correlation varying from 0.84 to 0.92 whereas it was only 0.70 in one lab. When total protein S antigen was reduced, protein S activity was decreased in all the patients with the 4 assays. In contrast when total protein S antigen was normal an important overlap of protein S activity between normals and patients was observed in one lab with 12 patients misclassified. In S patients with a functional defect, results of protein S activity differed substantially according to the assay used and about half of these patients were misclassified. In patients with inflammatory disease, protein S activity was normal with the 4 assays, in good correlation with free antigen, despite high levels of both C4bBP and total protein S antigen. In patients with oral anticoagulants, protein S activity was low with all assays. Only with one assay, protein S activity was significantly lower than free antigen, suggesting that this assay is sensitive to the hypo-carboxylated protein. Variable values of protein S activity were observed in patients with liver cirrhosis, with relatively little agreement between methods. As discordant results were obtained in some patients with dysfunctional protein S deficiency and acquired disorders, these methods do not necessarily measure the same cofactor of activated protein C. However this study indicates that all 4 functional protein S assays give similar results in normals, and almost all patients with a quantitative congenital deficiency.

Comparison of functional assays for protein S: European collabo¬rative study of patients with congenital and acquired deficiency / C. Boyer-Neumann, R.M. Bertina, A. Tripodi, A. D'angelo, M. Wolf, S. Vigano'-D'angelo, P.M. Mannucci, D. Meyer, M.J. Larrieu. - In: THROMBOSIS AND HAEMOSTASIS. - ISSN 0340-6245. - 70:6(1993), pp. 946-950.

Comparison of functional assays for protein S: European collabo¬rative study of patients with congenital and acquired deficiency

A. Tripodi;
1993

Abstract

Four functional assays for protein S were evaluated by 4 different laboratories, each center using its own method. The aim of this study was to compare these different assays and to establish a relationship with results of immunological assays of total and free protein S antigen and C4bBP. The same plasma samples were distributed to each center and tested in blind. In 47 normal subjects, there was no significant difference between the 4 functional assays, with mean values ranging from 93 to 100%. These values were in good agreement with those of free and total protein S antigen. In 34 patients with a quantitative congenital deficiency of protein S the mean values of protein S activity were decreased with the 4 assays, ranging from 25 to 40%. Free protein S antigen was reduced to a similar extent, whereas total antigen was either normal or decreased. The correlation of protein S activity with free protein S antigen was satisfactory for 3 methods, with coefficients of correlation varying from 0.84 to 0.92 whereas it was only 0.70 in one lab. When total protein S antigen was reduced, protein S activity was decreased in all the patients with the 4 assays. In contrast when total protein S antigen was normal an important overlap of protein S activity between normals and patients was observed in one lab with 12 patients misclassified. In S patients with a functional defect, results of protein S activity differed substantially according to the assay used and about half of these patients were misclassified. In patients with inflammatory disease, protein S activity was normal with the 4 assays, in good correlation with free antigen, despite high levels of both C4bBP and total protein S antigen. In patients with oral anticoagulants, protein S activity was low with all assays. Only with one assay, protein S activity was significantly lower than free antigen, suggesting that this assay is sensitive to the hypo-carboxylated protein. Variable values of protein S activity were observed in patients with liver cirrhosis, with relatively little agreement between methods. As discordant results were obtained in some patients with dysfunctional protein S deficiency and acquired disorders, these methods do not necessarily measure the same cofactor of activated protein C. However this study indicates that all 4 functional protein S assays give similar results in normals, and almost all patients with a quantitative congenital deficiency.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Settore MED/09 - Medicina Interna
Settore MED/15 - Malattie del Sangue
1993
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/189481
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 30
social impact