Rf values in various solvents are reported for a great many drugs of interest in forensic toxicol. The abs. values and the values cor. according to A. C. Moffat (1975) are tabulated. The acidic substances were chromatographed on alumina, the alk. ones on silica gel. The reproducibilities obtained upon repeated detn. of a given substance, whether pure or in exts. of biol. material, were greatly improved when the Moffat correction was applied, making the data more reliable for the identification of generic drugs. Similar tests were carried out on exts. of tissues, mostly treated by the Stas-Otto procedure; the exts. had been stored for 2-13 yr at room temp. in dark-glass, stoppered tubes, but without any other precaution. In almost all cases, the drugs in these exts. could be identified as readily by the chromatog. methods used as could the drugs in fresh material, as very little change had occurred during storage.

La ricerca chimico-tossicologica generica in tossicologia forense : nota V / E. Marozzi, F. Lodi, E. Saligari, V. Gambaro. - In: IL FARMACO. EDIZIONE PRATICA. - ISSN 0430-0912. - 35:10(1980), pp. 473-496.

La ricerca chimico-tossicologica generica in tossicologia forense : nota V

E. Marozzi
Primo
;
F. Lodi
Secondo
;
V. Gambaro
Ultimo
1980

Abstract

Rf values in various solvents are reported for a great many drugs of interest in forensic toxicol. The abs. values and the values cor. according to A. C. Moffat (1975) are tabulated. The acidic substances were chromatographed on alumina, the alk. ones on silica gel. The reproducibilities obtained upon repeated detn. of a given substance, whether pure or in exts. of biol. material, were greatly improved when the Moffat correction was applied, making the data more reliable for the identification of generic drugs. Similar tests were carried out on exts. of tissues, mostly treated by the Stas-Otto procedure; the exts. had been stored for 2-13 yr at room temp. in dark-glass, stoppered tubes, but without any other precaution. In almost all cases, the drugs in these exts. could be identified as readily by the chromatog. methods used as could the drugs in fresh material, as very little change had occurred during storage.
Settore CHIM/08 - Chimica Farmaceutica
1980
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/184794
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact