We compared two pre-column derivatization methods, o-phthaldialdehyde (OPA) and N,N-diethyl-2,4-dinitro-5-fluoroaniline (FDNDEA), for analysis of serum amino acids by reversed-phase high-performance liquid chromatography. Separations took 102 and 106 min for FDNDEA and OPA (reconditioning included), respectively, allowing a very good resolution of 30 amino acids by the former process and 38 by the latter. Linearity, within- and between-day variability and advantages in terms of accuracy and speed were studied for both methods. Twenty serum samples from healthy volunteers were assayed with OPA, FDNDEA and with the reference method of ion-exchange and post-column ninhydrin reaction (amino acid analyser), which took 170 min. The correlation between OPA and ninhydrin was good for all the amino acids (r = 0.959) except for the last-eluting lysine. Good agreement was found for FDNDEA (r = 0.987), which appeared in general to be a highly reproducible technique. Both pre-column methods were more sensitive than the post-column ninhydrin method.

SERUM AMINO-ACID-ANALYSIS WITH PRECOLUMN DERIVATIZATION - COMPARISON OF THE ORTHO-PHTHALDIALDEHYDE AND N,N-DIETHYL-2,4-DINITRO-5-FLUOROANILINE METHODS / I. FERMO, E. DEVECCHI, L. DIOMEDE, R. PARONI. - In: JOURNAL OF CHROMATOGRAPHY B. BIOMEDICAL APPLICATIONS. - ISSN 0378-4347. - 534:C(1990 Dec 14), pp. 23-35.

SERUM AMINO-ACID-ANALYSIS WITH PRECOLUMN DERIVATIZATION - COMPARISON OF THE ORTHO-PHTHALDIALDEHYDE AND N,N-DIETHYL-2,4-DINITRO-5-FLUOROANILINE METHODS

R. PARONI
Ultimo
1990

Abstract

We compared two pre-column derivatization methods, o-phthaldialdehyde (OPA) and N,N-diethyl-2,4-dinitro-5-fluoroaniline (FDNDEA), for analysis of serum amino acids by reversed-phase high-performance liquid chromatography. Separations took 102 and 106 min for FDNDEA and OPA (reconditioning included), respectively, allowing a very good resolution of 30 amino acids by the former process and 38 by the latter. Linearity, within- and between-day variability and advantages in terms of accuracy and speed were studied for both methods. Twenty serum samples from healthy volunteers were assayed with OPA, FDNDEA and with the reference method of ion-exchange and post-column ninhydrin reaction (amino acid analyser), which took 170 min. The correlation between OPA and ninhydrin was good for all the amino acids (r = 0.959) except for the last-eluting lysine. Good agreement was found for FDNDEA (r = 0.987), which appeared in general to be a highly reproducible technique. Both pre-column methods were more sensitive than the post-column ninhydrin method.
PERFORMANCE LIQUID-CHROMATOGRAPHY; PRECOLUMN DERIVATIZATION; ORTHO-PHTHALALDEHYDE; PLASMA; DERIVATIVES; PHENYLISOTHIOCYANATE; RESOLUTION; SEPARATION; PEPTIDE; VALUES
Settore BIO/10 - Biochimica
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
14-dic-1990
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/183688
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 35
social impact