A calorimeter using 30 tons of liquid krypton for the KEDR detector is being constructed. The main effects which determine the energy and space resolution have been studied. An energy resolution of 1.7% at 1.2 GeV was obtained with the prototype. A space resolution of 0.4 mm for relativistic particles has been reached with the prototype.

Liquid krypton electromagnetic calorimeter / V. Aulchenko, A. Bukin, S. Klimenko, G. Kolachev, L. Leontiev, A. Maslennikov, A. Onuchin, V. Panin, S. Peleganchuk, S. Pivovarov, V. Rodyakin, V. Tayursky, Y. Tikhonov, V. Yurchenko, F. Lanni, G. Lo Bianco, B. Maggi, F. Palombo, A. Sala, P. Cantoni, P. Frabetti, L. Stagni, P. Manfredi, V. Re, V. Speziali. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 327:1(1993), pp. 193-198. [10.1016/0168-9002(93)91440-X]

Liquid krypton electromagnetic calorimeter

F. Palombo;
1993

Abstract

A calorimeter using 30 tons of liquid krypton for the KEDR detector is being constructed. The main effects which determine the energy and space resolution have been studied. An energy resolution of 1.7% at 1.2 GeV was obtained with the prototype. A space resolution of 0.4 mm for relativistic particles has been reached with the prototype.
Settore FIS/04 - Fisica Nucleare e Subnucleare
1993
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/182882
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 10
social impact