A prototype lead-liquid-argon electromagnetic calorimeter with parallel plates and Accordion geometry has been equipped with high speed readout electronics and tested with electron and muon beams at the CERN SPS. For a response peaking time of about 35 ns, fast enough for operation at the future hadron colliders, the energy resolution for electrons is 9.6%/ square-root E[GeV] with a local constant term of 0.3% and a noise contribution of 0.33/E[GeV]. The spatial accuracy achieved with a detector granularity of 2.7 cm is 3.7 mm/ square-root E[GeV] and the angular resolution 12 mrad at 60 GeV.

PERFORMANCE OF A LIQUID ARGON ACCORDION CALORIMETER WITH FAST READOUT / B. AUBERT, A. BAZAN, B. BEAUGIRAUD, J. COLAS, T. LEFLOUR, M. MAIRE, J. VIALLE, I. WINGERTERSEEZ, Y. ZOLNIEROWSKI, H. GORDON, V. RADEKA, D. RAHM, D. STEPHANI, J. CHEVALLEY, C. FABJAN, D. FOURNIER, A. FRANZ, O. GILDEMEISTER, P. JENNI, M. NESSI, F. NESSITEDALDI, M. PEPE, W. RICHTER, J. SODERQVIST, J. BAZE, L. GOSSET, P. LAVOCAT, J. LOTTIN, B. MANSOULIE, J. MEYER, J. RENARDY, J. TEIGER, H. ZACCONE, G. BATTISTONI, D. CAMIN, D. CAVALLI, G. COSTA, A. CRAVERO, A. FERRARI, F. GIANOTTI, L. MANDELLI, M. MAZZANTI, L. PERINI, G. PESSINA, P. SALA, M. SCIAMANNA, E. AUGE, R. CHASE, J. CHOLLET, C. DELATAILLE, L. FAYARD, P. JEAN, L. ICONOMIDOUFAYARD, B. MERKEL, J. NOPPE, G. PARROUR, P. PETROFF, J. REPELLIN, A. SCHAFFER, N. SEGUIN, G. UNAL, C. FUGLESANG, M. LEFEBVRE, S. TOWERS. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 321:3(1992), pp. 467-478. [10.1016/0168-9002(92)90056-A]

PERFORMANCE OF A LIQUID ARGON ACCORDION CALORIMETER WITH FAST READOUT

L. Perini;
1992

Abstract

A prototype lead-liquid-argon electromagnetic calorimeter with parallel plates and Accordion geometry has been equipped with high speed readout electronics and tested with electron and muon beams at the CERN SPS. For a response peaking time of about 35 ns, fast enough for operation at the future hadron colliders, the energy resolution for electrons is 9.6%/ square-root E[GeV] with a local constant term of 0.3% and a noise contribution of 0.33/E[GeV]. The spatial accuracy achieved with a detector granularity of 2.7 cm is 3.7 mm/ square-root E[GeV] and the angular resolution 12 mrad at 60 GeV.
Settore FIS/04 - Fisica Nucleare e Subnucleare
1992
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/179983
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 28
social impact