A case of a severe paravalvular mechanical mitral prosthesis leak (PVL) in a high-risk surgical patient, complicated with acute heart failure at presentation is described. Considering the high surgical risk and the specific echocardiographic features that would prevent the interventional cardiologist to have a direct access to the PVL with a traditional vascular plug or duct occluder, a percutaneous PVL closure with an Amplatzer-Amulet (Abbott, Abbott Park, Illinois, United States) LAA device (28 mm) was chosen for the contiguity of the PVL to the left atrial appendage (LAA). A new-onset hemolysis post-PVL closure and severe renal failure requiring hemodialysis occurred after the procedure, treated with surgical device removal and leak suture. To the best of our knowledge, this is the first case that describes the attempt to close a PVL, contiguous to the LAA, using the Amulet device. The attempt to close a PVL with these features with an Amplatzer-Amulet device, although promising, does not appear completely safe to reach the goal, as in our case. In our opinion, the most important reasons are that specific technical recommendations and broad experiences are lacking. Indeed, specific outcomes of this kind of approach are, to date, still unknown.

Percutaneous closure of a paravalvular prosthetic mitral leak complicated by need for acute hemodialysis / F. Sozzi, N. Hugues, M. Schiavone, F. Levy, F. Civaia, L. Iacuzio, P. Rossi, S. Carugo, F. Bourlon, A. Eker. - In: JOURNAL OF CLINICAL ULTRASOUND. - ISSN 0091-2751. - (2021 Sep 04). [Epub ahead of print] [10.1002/jcu.23059]

Percutaneous closure of a paravalvular prosthetic mitral leak complicated by need for acute hemodialysis

S. Carugo;
2021

Abstract

A case of a severe paravalvular mechanical mitral prosthesis leak (PVL) in a high-risk surgical patient, complicated with acute heart failure at presentation is described. Considering the high surgical risk and the specific echocardiographic features that would prevent the interventional cardiologist to have a direct access to the PVL with a traditional vascular plug or duct occluder, a percutaneous PVL closure with an Amplatzer-Amulet (Abbott, Abbott Park, Illinois, United States) LAA device (28 mm) was chosen for the contiguity of the PVL to the left atrial appendage (LAA). A new-onset hemolysis post-PVL closure and severe renal failure requiring hemodialysis occurred after the procedure, treated with surgical device removal and leak suture. To the best of our knowledge, this is the first case that describes the attempt to close a PVL, contiguous to the LAA, using the Amulet device. The attempt to close a PVL with these features with an Amplatzer-Amulet device, although promising, does not appear completely safe to reach the goal, as in our case. In our opinion, the most important reasons are that specific technical recommendations and broad experiences are lacking. Indeed, specific outcomes of this kind of approach are, to date, still unknown.
Amulet-Amplatzer device; paravalvular leak; percutaneous closure; prosthetic mitral valve
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
4-set-2021
4-set-2021
Article (author)
File in questo prodotto:
File Dimensione Formato  
2021 J Clinical Ultras.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.11 MB
Formato Adobe PDF
1.11 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/865976
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact