MicroRNAs are widely studied as circulating biomarkers for early stage diagnosis of several diseases, but the procedures for their detection and quantification are currently complex and time consuming. We demonstrate a rapid, multiplex, one-pot detection method based on two-step amplification of the signal measured by a recent label-free optical biosensor, Reflective Phantom Interface (RPI). The specific capture with surface DNA probes is combined with mass amplification by an antibody targeting DNA–RNA hybrids and polyclonal secondary antibody, all performed without washing steps. Through this method, we achieved linear, sub-pM quantification of different miRNAs in 1.5 h. The RPI enabled the characterization of equilibrium and kinetics of each individual interaction involved in this multi-step process, which allowed us to model and optimize the relative concentrations and the time intervals of the assay.

Design and Optimization of a Rapid, Multiplex miRNA Assay without Washing Steps / G. Zanchetta, T. Carzaniga, L. Vanjur, L. Casiraghi, G. Tagliabue, C. Morasso, T.G. Bellini, M. Buscaglia. - In: PROCEEDINGS. - ISSN 2504-3900. - 60:1(2020), pp. 32.1-32.8. (Intervento presentato al 1. convegno International Electronic Conference on Biosensors nel 2020) [10.3390/iecb2020-07040].

Design and Optimization of a Rapid, Multiplex miRNA Assay without Washing Steps

G. Zanchetta;T. Carzaniga;L. Casiraghi;T.G. Bellini;M. Buscaglia
2020

Abstract

MicroRNAs are widely studied as circulating biomarkers for early stage diagnosis of several diseases, but the procedures for their detection and quantification are currently complex and time consuming. We demonstrate a rapid, multiplex, one-pot detection method based on two-step amplification of the signal measured by a recent label-free optical biosensor, Reflective Phantom Interface (RPI). The specific capture with surface DNA probes is combined with mass amplification by an antibody targeting DNA–RNA hybrids and polyclonal secondary antibody, all performed without washing steps. Through this method, we achieved linear, sub-pM quantification of different miRNAs in 1.5 h. The RPI enabled the characterization of equilibrium and kinetics of each individual interaction involved in this multi-step process, which allowed us to model and optimize the relative concentrations and the time intervals of the assay.
label-free biosensor; reflective phantom interface; nucleic acids; antibody; microRNA; DNA microarray; rapid detection; wash-free assay
Settore FIS/07 - Fisica Applicata(Beni Culturali, Ambientali, Biol.e Medicin)
2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
proceedings-60-00032.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 808.06 kB
Formato Adobe PDF
808.06 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/798390
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact