Asthma affects more than 330 million people worldwide, but many analyses have shown that there are still a lot of unmet needs for both patients and physicians in the treatment of asthma: poor adherence to treatment is one of the main causes of sub-optimal clinical results. Maintenance and Reliever Therapy (MART) with the combination of formoterol and inhaled corticosteroids (ICS) has an established scientific rationale and demonstrated to reduce asthma exacerbations. The aim of this review is to highlight how in asthmatic patients MART can be able to express its maximum therapeutic potential when administered through an 'ideal inhaler'. Since the treatment may be necessary several times a day, the use of a single combination inhaler simplifies the management, potentially improving adherence; moreover, easiness of use and comfort in administration of asthma treatment devices are not secondary aspects. Asthmatic patients are often young, with a normal relational and working life and they could request for a comfortable and not too noticeable device. Finally to the "ideal inhaler" is requested to guarantee accuracy, dose consistency, and resistance to stress conditions. Easyhaler® more closely demonstrates many expected characteristics: effective, consistent performance regardless of inspiration rate, stability, versatility, with several patient acceptability advantages. Asthma control is enhanced by a strong adherence obtained through the combination in a single inhaler of both maintenance and reliever therapy and the availability of a device as close as possible to the characteristics of the ideal inhaler.

Today's improvement in asthma treatment: role of MART and Easyhaler / F. Di Marco. - In: MULTIDISCIPLINARY RESPIRATORY MEDICINE. - ISSN 1828-695X. - 15:1(2020 Aug 05), pp. 649.1-649.6.

Today's improvement in asthma treatment: role of MART and Easyhaler

F. Di Marco
Primo
2020

Abstract

Asthma affects more than 330 million people worldwide, but many analyses have shown that there are still a lot of unmet needs for both patients and physicians in the treatment of asthma: poor adherence to treatment is one of the main causes of sub-optimal clinical results. Maintenance and Reliever Therapy (MART) with the combination of formoterol and inhaled corticosteroids (ICS) has an established scientific rationale and demonstrated to reduce asthma exacerbations. The aim of this review is to highlight how in asthmatic patients MART can be able to express its maximum therapeutic potential when administered through an 'ideal inhaler'. Since the treatment may be necessary several times a day, the use of a single combination inhaler simplifies the management, potentially improving adherence; moreover, easiness of use and comfort in administration of asthma treatment devices are not secondary aspects. Asthmatic patients are often young, with a normal relational and working life and they could request for a comfortable and not too noticeable device. Finally to the "ideal inhaler" is requested to guarantee accuracy, dose consistency, and resistance to stress conditions. Easyhaler® more closely demonstrates many expected characteristics: effective, consistent performance regardless of inspiration rate, stability, versatility, with several patient acceptability advantages. Asthma control is enhanced by a strong adherence obtained through the combination in a single inhaler of both maintenance and reliever therapy and the availability of a device as close as possible to the characteristics of the ideal inhaler.
asthma; anti-asthmatic agents; budesonide formoterol fumarate drug combination; inhalation device; treatment adherence and compliance
Settore MED/10 - Malattie dell'Apparato Respiratorio
5-ago-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
649-Article Text-3323-3-10-20200805.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 569.99 kB
Formato Adobe PDF
569.99 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/783252
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact