Background: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. Methods: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. Results: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p =.001), due to more cardiac deaths (3.4 vs. 1.1%; p =.002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p =.114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p =.526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p =.041), but similar rate of TLR (6 vs. 4%; p =.405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. Conclusions: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.

One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in diabetic patients: Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry) / A. Beneduce, G. Ferrante, A. Ielasi, C.A. Pivato, M. Chiarito, A. Cappelletti, L. Baldetti, V. Magni, E. Prati, S. Falcone, A. Pierri, S. De Martini, M. Montorfano, R. Parisi, D. Rutigliano, N. Locuratolo, A. Anzuini, M. Tespili, A. Margonato, A. Benassi, C. Briguori, B. Reimers, F. Fabbiocchi, A. Bartorelli, A. Colombo, C. Godino. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - 96:2(2020 Aug), pp. 255-265.

One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in diabetic patients: Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry)

A. Bartorelli;
2020

Abstract

Background: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. Methods: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. Results: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p =.001), due to more cardiac deaths (3.4 vs. 1.1%; p =.002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p =.114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p =.526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p =.041), but similar rate of TLR (6 vs. 4%; p =.405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. Conclusions: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.
biodegradable polymer sirolimus-eluting stent; diabetes mellitus; percutaneous coronary intervention
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
ago-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
One.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/772436
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact