Objectives: The aim of the BIOLUX P-III (A Prospective, International, Multi-Centre, Post-Market All-Comers Registry to Assess the Clinical Performance of the Passeo-18 Lux Paclitaxel Releasing Balloon Catheter in Infrainguinal Arteries - III) registry was to collect real-world data on the Passeo-18 Lux paclitaxel-coated balloon. Background: Critical limb ischemia (CLI) is a severe condition associated with high morbidity and mortality. Prospective data are needed to provide further insights on drug-eluting devices. Methods: BIOLUX P-III is a prospective, post-market, all-comers registry assessing the safety and performance of the Passeo-18 Lux. Clinical information was collected at 6, 12, and 24 months. The authors report 24-month outcomes of the CLI subgroup with patients in Rutherford classes 4 to 6. Results: The CLI subgroup included 328 patients with 422 lesions. Patients were 71.1 ± 10.5 years of age, and 61.0% had diabetes. Femoropopliteal lesions were present in 53.8% (n = 227), below-the-knee lesions were present in 27.0% (n = 114), and lesions were moderate or heavily calcified in 45.0% (n = 190). Major adverse events, defined as 30-day device- or procedure-related mortality, major target limb amputation, and clinically driven target lesion revascularization, occurred in 9.8% of patients through 6 months, in 14.9% through 12 months, and in 19.4% through 24 months. Clinically driven target lesion revascularization occurred in 4.4%, 8.5%, and 12.1%, major amputation in 4.9%, 5.2%, and 6.1%, and mortality in 8.1%, 11.1%, and 20.1%, respectively. Predictors of mortality were age ≥75 years and higher Trans-Atlantic Inter-Society Consensus Document on Management of Peripheral Arterial Disease class, and higher Rutherford class was associated with increased mortality and amputation rates. Conclusions: In a large, multimorbid patient population with complex lesions and CLI, the safety and performance of the Passeo-18 Lux paclitaxel-coated balloon has been confirmed, with low rates of major amputation and target lesion revascularization.

Real-World Experience With a Paclitaxel-Coated Balloon in Critical Limb Ischemia: 24-Month Subgroup Outcomes of BIOLUX P-III / M. Brodmann, M. Moscovic, J.C.C. Wang, G. Nano, J. Dahm, T. Zeller, J.K. Christensen, K. Keirse, R. Ghotbi, J. Corpataux, G. Tepe. - In: JACC: CARDIOVASCULAR INTERVENTIONS. - ISSN 1936-8798. - (2020 Sep 11). [Epub ahead of print] [10.1016/j.jcin.2020.06.059]

Real-World Experience With a Paclitaxel-Coated Balloon in Critical Limb Ischemia: 24-Month Subgroup Outcomes of BIOLUX P-III

G. Nano;
2020

Abstract

Objectives: The aim of the BIOLUX P-III (A Prospective, International, Multi-Centre, Post-Market All-Comers Registry to Assess the Clinical Performance of the Passeo-18 Lux Paclitaxel Releasing Balloon Catheter in Infrainguinal Arteries - III) registry was to collect real-world data on the Passeo-18 Lux paclitaxel-coated balloon. Background: Critical limb ischemia (CLI) is a severe condition associated with high morbidity and mortality. Prospective data are needed to provide further insights on drug-eluting devices. Methods: BIOLUX P-III is a prospective, post-market, all-comers registry assessing the safety and performance of the Passeo-18 Lux. Clinical information was collected at 6, 12, and 24 months. The authors report 24-month outcomes of the CLI subgroup with patients in Rutherford classes 4 to 6. Results: The CLI subgroup included 328 patients with 422 lesions. Patients were 71.1 ± 10.5 years of age, and 61.0% had diabetes. Femoropopliteal lesions were present in 53.8% (n = 227), below-the-knee lesions were present in 27.0% (n = 114), and lesions were moderate or heavily calcified in 45.0% (n = 190). Major adverse events, defined as 30-day device- or procedure-related mortality, major target limb amputation, and clinically driven target lesion revascularization, occurred in 9.8% of patients through 6 months, in 14.9% through 12 months, and in 19.4% through 24 months. Clinically driven target lesion revascularization occurred in 4.4%, 8.5%, and 12.1%, major amputation in 4.9%, 5.2%, and 6.1%, and mortality in 8.1%, 11.1%, and 20.1%, respectively. Predictors of mortality were age ≥75 years and higher Trans-Atlantic Inter-Society Consensus Document on Management of Peripheral Arterial Disease class, and higher Rutherford class was associated with increased mortality and amputation rates. Conclusions: In a large, multimorbid patient population with complex lesions and CLI, the safety and performance of the Passeo-18 Lux paclitaxel-coated balloon has been confirmed, with low rates of major amputation and target lesion revascularization.
chronic limb-threatening ischemia; critical limb ischemia; drug-coated balloon; drug-eluting balloon; peripheral artery disease
Settore MED/22 - Chirurgia Vascolare
11-set-2020
Article (author)
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1936879820314746-main.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 808.28 kB
Formato Adobe PDF
808.28 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/768998
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 6
social impact