OBJECTIVES: Lung CT is the reference imaging technique for acute respiratory distress syndrome, but requires transportation outside the intensive care and x-ray exposure. Lung ultrasound is a promising, inexpensive, radiation-free, tool for bedside imaging. Aim of the present study was to compare the global and regional diagnostic accuracy of lung ultrasound and CT scan. DESIGN: A prospective, observational study. SETTING: Intensive care and radiology departments of a University hospital. PATIENTS: Thirty-two sedated, paralyzed acute respiratory distress syndrome patients (age 65 ± 14 yr, body mass index 25.9 ± 6.5 kg/m, and PaO2/FIO2 139 ± 47). INTERVENTIONS: Lung CT scan and lung ultrasound were performed at positive end-expiratory pressure 5 cm H2O. A standardized assessment of six regions per hemithorax was used; each region was classified for the presence of normal aeration, alveolar-interstitial syndrome, consolidation, and pleural effusion. Agreement between the two techniques was calculated, and diagnostic variables were assessed for lung ultrasound using lung CT as a reference. MEASUREMENTS AND MAIN RESULTS: Global agreement between lung ultrasound and CT ranged from 0.640 (0.391-0.889) to 0.934 (0.605-1.000) and was on average 0.775 (0.577-0.973). The overall sensitivity and specificity of lung ultrasound ranged from 82.7% to 92.3% and from 90.2% to 98.6%, respectively. Similar results were found with regional analysis. The diagnostic accuracy of lung ultrasound was significantly higher when those patterns not reaching the pleural surface were excluded (area under the receiver operating characteristic curve: alveolar-interstitial syndrome 0.854 [0.821-0.887] vs 0.903 [0.852-0.954]; p = 0.049 and consolidation 0.851 [0.818-0.884] vs 0.896 [0.862-0.929]; p = 0.044). CONCLUSIONS: Lung ultrasound is a reproducible, sensitive, and specific tool, which allows for bedside detections of the morphologic patterns in acute respiratory distress syndrome. The presence of deep lung alterations may impact the diagnostic performance of this technique.

Global and Regional Diagnostic Accuracy of Lung Ultrasound Compared to CT in Patients With Acute Respiratory Distress Syndrome / D. Chiumello, M. Umbrello, G.F. Sferrazza Papa, A. Angileri, M. Gurgitano, P. Formenti, S. Coppola, S. Froio, A. Cammaroto, G. Carrafiello. - In: CRITICAL CARE MEDICINE. - ISSN 1530-0293. - 47:11(2019 Nov), pp. 1599-1606.

Global and Regional Diagnostic Accuracy of Lung Ultrasound Compared to CT in Patients With Acute Respiratory Distress Syndrome

D. Chiumello
;
M. Umbrello;G.F. Sferrazza Papa;M. Gurgitano;A. Cammaroto;G. Carrafiello
2019

Abstract

OBJECTIVES: Lung CT is the reference imaging technique for acute respiratory distress syndrome, but requires transportation outside the intensive care and x-ray exposure. Lung ultrasound is a promising, inexpensive, radiation-free, tool for bedside imaging. Aim of the present study was to compare the global and regional diagnostic accuracy of lung ultrasound and CT scan. DESIGN: A prospective, observational study. SETTING: Intensive care and radiology departments of a University hospital. PATIENTS: Thirty-two sedated, paralyzed acute respiratory distress syndrome patients (age 65 ± 14 yr, body mass index 25.9 ± 6.5 kg/m, and PaO2/FIO2 139 ± 47). INTERVENTIONS: Lung CT scan and lung ultrasound were performed at positive end-expiratory pressure 5 cm H2O. A standardized assessment of six regions per hemithorax was used; each region was classified for the presence of normal aeration, alveolar-interstitial syndrome, consolidation, and pleural effusion. Agreement between the two techniques was calculated, and diagnostic variables were assessed for lung ultrasound using lung CT as a reference. MEASUREMENTS AND MAIN RESULTS: Global agreement between lung ultrasound and CT ranged from 0.640 (0.391-0.889) to 0.934 (0.605-1.000) and was on average 0.775 (0.577-0.973). The overall sensitivity and specificity of lung ultrasound ranged from 82.7% to 92.3% and from 90.2% to 98.6%, respectively. Similar results were found with regional analysis. The diagnostic accuracy of lung ultrasound was significantly higher when those patterns not reaching the pleural surface were excluded (area under the receiver operating characteristic curve: alveolar-interstitial syndrome 0.854 [0.821-0.887] vs 0.903 [0.852-0.954]; p = 0.049 and consolidation 0.851 [0.818-0.884] vs 0.896 [0.862-0.929]; p = 0.044). CONCLUSIONS: Lung ultrasound is a reproducible, sensitive, and specific tool, which allows for bedside detections of the morphologic patterns in acute respiratory distress syndrome. The presence of deep lung alterations may impact the diagnostic performance of this technique.
Settore MED/36 - Diagnostica per Immagini e Radioterapia
nov-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
00003246-201911000-00016.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 161.12 kB
Formato Adobe PDF
161.12 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/723831
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 51
social impact