Introduction: Neutrophil elastase activity in sputum can identify patients at high risk of airway infection and exacerbations in bronchiectasis. Application of this biomarker in clinical practice is limited, because no point-of-care test is available. We tested whether a novel semi-quantitative lateral flow device (neutrophil elastase airway test stick - NEATstik®) can stratify bronchiectasis patients according to severity, airway infection and exacerbation risk. Methods: Sputum samples from 124 patients with stable bronchiectasis enrolled in the UK and Spain were tested using the NEATstik®, which scores neutrophil elastase concentration from 0 (<8 μg·mL-1 elastase activity) to 10 (maximum detectable neutrophil elastase activity). High neutrophil elastase activity was regarded as a NEATstik® grade >6. Severity of disease, airway infection from sputum culture and exacerbations over the 12 months were recorded. An independent validation was conducted in 50 patients from Milan, Italy. Measurements and main results: Patients had a median age of 69 years and forced expiratory volume in 1 s (FEV1) 69%. High neutrophil elastase activity was associated with worse bronchiectasis severity using the bronchiectasis severity index (p=0.0007) and FEV1 ( p=0.02). A high NEATstik® grade was associated with a significant increase in exacerbation frequency, incident rate ratio 2.75 (95% CI 1.63-4.64, p<0.001). The median time to next exacerbation for patients with a NEATstik® grade >6 was 103 days compared to 278 days. The hazard ratio was 2.59 (95% CI 1.71-3.94, p<0.001). Results were confirmed in the independent validation cohort. Conclusions: A novel lateral flow device provides assessment of neutrophil elastase activity from sputum in minutes and identifies patients at increasing risk of airway infection and future exacerbations.

A point-of-care neutrophil elastase activity assay identifies bronchiectasis severity, airway infection and risk of exacerbation / A. Shoemark, E. Cant, L. Carreto, A. Smith, M. Oriano, H. Keir, L. Perea, E. Canto, L. Terranova, S. Vidal, K. Moffitt, S. Aliberti, O. Sibila, J.D. Chalmers. - In: EUROPEAN RESPIRATORY JOURNAL. - ISSN 0903-1936. - 53:6(2019 Jun), pp. 1900303.1-1900303.9. [10.1183/13993003.00303-2019]

A point-of-care neutrophil elastase activity assay identifies bronchiectasis severity, airway infection and risk of exacerbation

M. Oriano;L. Terranova;S. Aliberti;
2019

Abstract

Introduction: Neutrophil elastase activity in sputum can identify patients at high risk of airway infection and exacerbations in bronchiectasis. Application of this biomarker in clinical practice is limited, because no point-of-care test is available. We tested whether a novel semi-quantitative lateral flow device (neutrophil elastase airway test stick - NEATstik®) can stratify bronchiectasis patients according to severity, airway infection and exacerbation risk. Methods: Sputum samples from 124 patients with stable bronchiectasis enrolled in the UK and Spain were tested using the NEATstik®, which scores neutrophil elastase concentration from 0 (<8 μg·mL-1 elastase activity) to 10 (maximum detectable neutrophil elastase activity). High neutrophil elastase activity was regarded as a NEATstik® grade >6. Severity of disease, airway infection from sputum culture and exacerbations over the 12 months were recorded. An independent validation was conducted in 50 patients from Milan, Italy. Measurements and main results: Patients had a median age of 69 years and forced expiratory volume in 1 s (FEV1) 69%. High neutrophil elastase activity was associated with worse bronchiectasis severity using the bronchiectasis severity index (p=0.0007) and FEV1 ( p=0.02). A high NEATstik® grade was associated with a significant increase in exacerbation frequency, incident rate ratio 2.75 (95% CI 1.63-4.64, p<0.001). The median time to next exacerbation for patients with a NEATstik® grade >6 was 103 days compared to 278 days. The hazard ratio was 2.59 (95% CI 1.71-3.94, p<0.001). Results were confirmed in the independent validation cohort. Conclusions: A novel lateral flow device provides assessment of neutrophil elastase activity from sputum in minutes and identifies patients at increasing risk of airway infection and future exacerbations.
Settore MED/10 - Malattie dell'Apparato Respiratorio
giu-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
1900303.full.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Dimensione 628.67 kB
Formato Adobe PDF
628.67 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/666809
Citazioni
  • ???jsp.display-item.citation.pmc??? 19
  • Scopus 53
  • ???jsp.display-item.citation.isi??? 45
social impact