BACKGROUND: The purpose of this study was to prospectively test the accuracy of computer-aided orthognathic surgery comparing the virtual surgical planning with the three-dimensional (3D) outcome. METHODS: Patients that underwent computer-assisted orthognathic surgery were retrospectively evaluated. The postoperative results were compared with the surgical plan, superimposing the postoperative computed tomography (CT) scan onto the virtual plan. Surface-based superimpositioning of the postoperative CT scan onto the 3D preoperative plan was carried out to visualize the discrepancy between preoperative virtual plan and postoperative 3D CT result. RESULTS: A total of 17 consecutive patients that underwent two-jaw computer-assisted orthognathic surgery were enrolled in the study.The average linear differences for selected points were <1 mm in 12 patients out of 17. In 5 patients out of 17, the average differences for selected points were <2 mm. CONCLUSIONS: An overall high degree of accuracy between the virtual plan and the postoperative result was found.

Evaluation of the Accuracy of Virtual Planning in Orthognathic Surgery : a Morphometric Study / E. Zavattero, M. Romano, G. Gerbino, D.S. Rossi, A.B. Gianni, G. Ramieri, A. Baj. - In: THE JOURNAL OF CRANIOFACIAL SURGERY. - ISSN 1049-2275. - 30:4(2019 Jun), pp. 1214-1220.

Evaluation of the Accuracy of Virtual Planning in Orthognathic Surgery : a Morphometric Study

A.B. Gianni;A. Baj
2019

Abstract

BACKGROUND: The purpose of this study was to prospectively test the accuracy of computer-aided orthognathic surgery comparing the virtual surgical planning with the three-dimensional (3D) outcome. METHODS: Patients that underwent computer-assisted orthognathic surgery were retrospectively evaluated. The postoperative results were compared with the surgical plan, superimposing the postoperative computed tomography (CT) scan onto the virtual plan. Surface-based superimpositioning of the postoperative CT scan onto the 3D preoperative plan was carried out to visualize the discrepancy between preoperative virtual plan and postoperative 3D CT result. RESULTS: A total of 17 consecutive patients that underwent two-jaw computer-assisted orthognathic surgery were enrolled in the study.The average linear differences for selected points were <1 mm in 12 patients out of 17. In 5 patients out of 17, the average differences for selected points were <2 mm. CONCLUSIONS: An overall high degree of accuracy between the virtual plan and the postoperative result was found.
Accuracy; orthognathic surgery; virtual planning
Settore MED/29 - Chirurgia Maxillofacciale
giu-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
Evaluation_of_the_Accuracy_of_Virtual_Planning_in.59.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 435.42 kB
Formato Adobe PDF
435.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/658303
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 21
social impact