A facile, ultra-sensitive, quickly recoverable, and room temperature operating ammonia sensor was developed by using polyaniline (PANI) and hematite (α-Fe2O3) hybrid nanocomposite. The hematite nanoparticles were obtained by template-free hydrothermal process. The PANI/α-Fe2O3 nanocomposite was synthesized by in situ chemical oxidative polymerization process of aniline in presence of α-Fe2O3 nanoparticles. The structural and morphological study and compositional analysis of PANI/α-Fe2O3 were performed by Fourier transform infrared spectroscopy, X-ray powder diffraction analysis, and scanning electron microscopy. The PANI/α-Fe2O3 sensor showed excellent reproducibility, ultra-fast response, and excellent sensitivity (46.72%) as compared to PANI (29.72%) sensor towards ammonia gas at room temperature.

Room temperature operating sensitive and reproducible ammonia sensor based on PANI/hematite nanocomposite / M.A. Bora, P.B. Adhav, B.B. Diwate, D.S. Pawar, S. Dallavalle, V.V. Chabukswar. - In: POLYMER-PLASTICS TECHNOLOGY AND MATERIALS. - ISSN 2574-0881. - (2019 Jan 17). [Epub ahead of print] [10.1080/25740881.2018.1563131]

Room temperature operating sensitive and reproducible ammonia sensor based on PANI/hematite nanocomposite

S. Dallavalle
Penultimo
;
2019

Abstract

A facile, ultra-sensitive, quickly recoverable, and room temperature operating ammonia sensor was developed by using polyaniline (PANI) and hematite (α-Fe2O3) hybrid nanocomposite. The hematite nanoparticles were obtained by template-free hydrothermal process. The PANI/α-Fe2O3 nanocomposite was synthesized by in situ chemical oxidative polymerization process of aniline in presence of α-Fe2O3 nanoparticles. The structural and morphological study and compositional analysis of PANI/α-Fe2O3 were performed by Fourier transform infrared spectroscopy, X-ray powder diffraction analysis, and scanning electron microscopy. The PANI/α-Fe2O3 sensor showed excellent reproducibility, ultra-fast response, and excellent sensitivity (46.72%) as compared to PANI (29.72%) sensor towards ammonia gas at room temperature.
Settore CHIM/08 - Chimica Farmaceutica
Settore CHIM/06 - Chimica Organica
17-gen-2019
17-gen-2019
Article (author)
File in questo prodotto:
File Dimensione Formato  
2019 PANIbis.pdf

accesso riservato

Tipologia: Pre-print (manoscritto inviato all'editore)
Dimensione 527.62 kB
Formato Adobe PDF
527.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Room temperature operating sensitive and reproducible ammonia sensor based on PANI hematite nanocomposite.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 2.75 MB
Formato Adobe PDF
2.75 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/636642
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 16
social impact